ALABASTER, AL ·
OSHA Inspection: E-BOX, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of E-BOX, INC. in 101 AIRPARK INDUSTRIAL ROAD, ALABASTER, AL 35007 (NAICS 335313). OSHA activity number 340030394.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- E-BOX, INC.
- Site address
- 101 AIRPARK INDUSTRIAL ROAD
- City
- ALABASTER
- State
- AL
- ZIP
- 35007
- Mailing
- 101 AIRPARK INDUSTRIAL ROAD, ALABASTER, AL 35007
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335313
- Employees
- 55
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.107 H12
- Issued
- Feb 20, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $3,150 · Current $1,890 Reduced
9135B101
General-duty citation text
29 CFR 1910.107(h)(12): All areas used for spraying, including the interior of the booth, were not protected by an automatic sprinklers or other approved automatic extinguishing equipment: (a) On or about 10/30/14 - E-1 (Manual) Booth, the electrostatic powder spraying booth was not protected by automatic extinguishing equipment. (b) On or about 10/20/14 - E-2 (Automated) Booth, the electrostatic powder spraying booth was not protected by automatic extinguishing equipment.
Recent events (2)
- · I (S) $1890
- · Z (S) $3150
1910.107 I04
- Issued
- Feb 20, 2015
- Abate by
- Mar 18, 2015
- Penalty
- Initial $3,150 · Current $1,890 Reduced
9135B101
General-duty citation text
29 CFR 1910.107(i)(4): Transformers, power packs, control apparatus, and all other electrical portions of the equipment, with the exception of high-voltage grids, electrodes, and electrostatic atomizing heads and their connections, were not located outside of the spraying area, and did not otherwise conform to the requirements of paragraph (c) of this section: (a) On or about 10/30/14 - E-1 (Manual) Booth, the Nordson Encore power pack spray equipment was located inside the spray booth.
Recent events (2)
- · I (S) $1890
- · Z (S) $3150
1910.107 I08
- Issued
- Feb 20, 2015
- Abate by
- Apr 8, 2015
- Penalty
- Initial $0 · Current $0
9135B101
General-duty citation text
29 CFR 1910.107(i)(8): The electrical equipment was not interlocked with the ventilation of the spraying area that the equipment could not be operated unless the ventilation fans were in operation: (a) On or about 10/30/14 - E-1 (Manual) Booth, electrostatic hand spraying equipment was not interlocked with the ventilation of the spray booth. (b) On or about 10/30/14 - E-2 (Automated) Booth, electrostatic hand spraying equipment was not interlocked with the ventilation of the spray booth.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1000 A02
- Issued
- Feb 20, 2015
- Abate by
- Aug 14, 2015
- Penalty
- Initial $3,150 · Current $1,890 Reduced
9135
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Total Dust (Particulates Not Otherwise Regulated) listed in Table Z-1 in excess of the 8 hour Time-Weighted Average concentration of 15 mg/m3: a. On or about 10/30/2014 - Conveyed Spray Line, the employee performing electrostatic painting was exposed to an 8-hour time weighted average of 120.00 mg/m3 of Total Dust, approximately 8 times the permissible exposure limit (PEL) of 15 mg/m3. The employee was sampled for 360 minutes during one shift on 10/30/14. Zero exposure was assumed for the unsampled time of 120 minutes. b. On or about 10/30/2014 - Manual Spray Line, the employee performing electrostatic painting was exposed to an 8-hour time weighted average of 43.40 mg/m3 of Total Dust, approximately 2.9 times the permissible exposure limit (PEL) of 15 mg/m3. The employee was sampled for 425 minutes during one shift on 10/30/14. Zero exposure was assumed for the unsampled time of 55 minutes.
Recent events (2)
- · I (S) $1890
- · Z (S) $3150
1910.1000 E
- Issued
- Feb 20, 2015
- Abate by
- Aug 14, 2015
- Penalty
- Initial $0 · Current $0
9135
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): (a) On or about 10/30/2014 - Conveyed Spray Line, the painter was exposed to an 8-hour time weighted average of 120.00 mg/m3 of Total Dust, approximately 8 times the permissible exposure limit (PEL) of 15 mg/m3. The employee was sampled for 360 minutes during one shift on 10/30/14. Zero exposure was assumed for the unsampled time of 120 minutes. (b) On or about 10/30/2014 - Manual Spray Line, the painter was exposed to an 8-hour time weighted average of 43.40 mg/m3 of Total Dust, approximately 2.9 times the permissible exposure limit (PEL) of 15 mg/m3. The employee was sampled for 425 minutes during one shift on 10/30/14. Zero exposure was assumed for the unsampled time of 55 minutes. General Methods of abatement include but are not limited to: 1. Installation of local exhaust/dust collection along the shakeout line. 2. Modifications of work assignments, such as using rotation to reduce employees' exposure.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV C
- Issued
- Feb 20, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows or floors. a) On or about 10/30/2014 - E-1 (Manual) Spray Booth, a flexible cord was run from the inside of a spray booth through the door and plugged into the outside of the booth.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.334 A02 I
- Issued
- Feb 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) On or about 10/30/2014 - E-1 (Manual) Spray Booth, an extendable extension cord used to provide electrical power to the Nordson electrostatic sprayer had damaged outer insulation.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at E-Box, INC.
View E-Box, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335313)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340030394.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.