HOMESTEAD, FL ·
OSHA Inspection: V.V.C. SERVICES, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of V.V.C. SERVICES, INC. in 11863 SW 250 TERRACE LOT #13-4, HOMESTEAD, FL 33032 (NAICS 236115). OSHA activity number 340040443.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- V.V.C. SERVICES, INC.
- Site address
- 11863 SW 250 TERRACE LOT #13-4
- City
- HOMESTEAD
- State
- FL
- ZIP
- 33032
- Mailing
- PO BOX 59, HALLANDALE, FL 33008
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 7
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.404 F03 I B
- Issued
- Jan 29, 2015
- Abate by
- Feb 4, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.404(f)(3)(i)(B): The noncurrent-carrying metal parts of equipment and the equipment grounding conductor terminals of the receptacles were not bonded to the generator frame: On or about 10/27/2014, at the above addressed location, employees were using a portable generator that did not have the grounding conductor bonded to the frame.
Recent events (1)
- · Z (S) $1600
1926.501 B10
- Issued
- Jan 29, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system: On or about 10/27/2014, at the above addressed location, employees working on a low sloped roof did not have any fall protection exposing them to a fall hazard of approximately 15-feet.
Recent events (1)
- · Z (S) $2800
1926.502 H01
- Issued
- Jan 29, 2015
- Abate by
- Feb 4, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.502(h)(1): The employer did not did not designate a competent person to monitor the safety of other employees and/or did not ensure that the safety monitor complied with the requirements listed in (h)(1)(i) through (h)(1)(v) of this section: On or about 10/27/2014, at the above addressed location, the employer did not designate a competent person to manage the fall protection plan and monitor the safety of the other employees on the roof.
Recent events (1)
- · Z (S) $2800
1926.503 A01
- Issued
- Jan 29, 2015
- Abate by
- Feb 10, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about 10/27/2014, at the above addressed location, the employer did not provide a training program for employees working on a roof without fall protection.
Recent events (1)
- · Z (S) $2800
1926.503 B01
- Issued
- Jan 29, 2015
- Abate by
- Feb 10, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: On or about 10/27/2014, at the above addressed location, the employer did not verify compliance with the required fall protection training by a certification record.
Recent events (1)
- · Z (S) $2800
1926.1053 B01
- Issued
- Jan 29, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about 10/27/2014, at the above addressed location, employees were exposed to a fall hazard while using a ladder to access the roof and the ladder did not extend at least 3-feet above the landing surface.
Recent events (1)
- · Z (S) $1600
1926.1060 A01 III
- Issued
- Jan 29, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and stairways had been trained by a competent person in the proper construction, use, placement, and care in handling of all stairways and ladders: On or about 10/27/2014, at the above addressed location, the employer did not ensure that employees using portable ladders had been trained in the proper use and placement.
Recent events (1)
- · Z (S) $1600
More inspections at V.V.C. Services, INC.
View V.V.C. Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340040443.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.