Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MALTEUROP NORTH AMERICA INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MALTEUROP NORTH AMERICA INC. in 3830 W. GRANT STREET, MILWAUKEE, WI 53215 (NAICS 311213). OSHA activity number 340050475.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Malteurop North America INC. — free Get an email when a new federal OSHA severe-injury report for Malteurop North America INC. is published. One employer, no account, unsubscribe in one click.
Site address
3830 W. GRANT STREET
City
MILWAUKEE
State
WI
ZIP
53215
Mailing
3830 W. GRANT STREET, MILWAUKEE, WI 53215
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311213
Employees
80
Ownership type
A

8 citations on file for this inspection.

1910.23 A08 II

Serious Gravity 5 1 instance 36 exposed
Issued
Mar 27, 2015
Abate by
Apr 21, 2015
Penalty
Initial $5,940 · Current $4,500 Reduced
29 CFR 1910.23(a)(8)(ii): A floor hole cover of standard strength and construction. While the cover is not in place, the floor hole shall be constantly attended by someone or shall be protected by a removable standard railing.      a)  The 18.5 long by 3.5 foot wide pit with 10 by 10 inch openings in the germination room on floor #4 in malt house #3 was not protected on all sides to prevent employees from falling into the space during transfer of grain between the germination operations.
Recent events (3)
  • — F (S) $4500
  • — C (S) $5940
  • — Z (S) $5940

1910.132 C

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 27, 2015
Abate by
Apr 22, 2015
Penalty
Initial $3,960 · Current $0 Reduced
29 CFR 1910.132(c): Personal protective equipment was not of safe design and construction for the work to be performed:    (a) The employer failed to ensure that the anchorage points utilized for fall arrest systems were evaluated by a qualified person to ensure that they were able to withstand the minimum requirements to safely arrest a fall.
Recent events (3)
  • — F (S) $0
  • — C (S) $3960
  • — Z (S) $3960

1910.134 D01 III

Serious Gravity 5 1 instance 30 exposed
Issued
Mar 27, 2015
Abate by
Apr 21, 2015
Penalty
Initial $3,960 · Current $4,500
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:    a)  The employer had not performed an evaluation of potential exposures to respiratory hazards of grain dust such as but not limited to wheat and barley dust in areas where respirators are used by employees.
Recent events (3)
  • — F (S) $4500
  • — C (S) $3960
  • — Z (S) $3960

1910.134 G02 I

Serious Gravity 5 1 instance 30 exposed
Issued
Mar 27, 2015
Abate by
Apr 21, 2015
Penalty
Initial $3,960 · Current $0 Reduced
29 CFR 1910.134(g)(2)(i): When there was a change in the work area, conditions, or degree of employee exposure or stress that may effect respirator effectiveness, the employer did not reevaluate the continued effectiveness of the respirator:    a)  The employer did not evaluate the effectiveness of the 3M full face and disposable 3M 8210 N-95 dust/mist respirators when changes were made such as the addition of wheat to the malting process and the inadequate dust collection system on top of malt house #3 above steeping.
Recent events (3)
  • — F (S) $0
  • — C (S) $3960
  • — Z (S) $3960

1910.134 G01 I A

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 27, 2015
Abate by
Apr 10, 2015
Penalty
Initial $3,960 · Current $4,500
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting face pieces were worn by employees who had facial hair that came between the sealing surface of the face piece and the face or that interfered with valve function:    a)  The employer did not ensure that employees using respiratory protection, which included full face 3M elastomeric respirators, were cleanly shaven.
Recent events (3)
  • — F (S) $4500
  • — C (S) $3960
  • — Z (S) $3960

1910.134 H02 I

Serious Gravity 5 1 instance 30 exposed
Issued
Mar 27, 2015
Abate by
Apr 21, 2015
Penalty
Initial $3,960 · Current $0 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    a)  Disposable 3M 8210 dust/mist respirators and 3M full face respirators being used by employees were stored in employee lockers hanging from hooks, equipment storage lockers and on surfaces face up, subjecting them to contamination and dust from the malting operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $3960
  • — Z (S) $3960

1910.305 G01 IV C

Other-than-serious 1 instance 2 exposed
Issued
Mar 27, 2015
Penalty
Initial $2,970 · Current $2,000 Reduced
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows or floors:    a)  On or about October 30, 2014, the extension cord being used for repairs from the scaffold outside of malt house #3 was attached to an outlet through a closed window.
Recent events (3)
  • — F (O) $2000
  • — C (S) $2970
  • — Z (S) $2970

1910.305 G01 IV D

Other-than-serious 1 instance 2 exposed
Issued
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:    a)  On or about October 30, 2014, the extension cord used for repairs outside malt house #3 was run through a closed window and wrapped around building pipes.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

View Malteurop North America INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340050475.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.