Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MALTEUROP NORTH AMERICA INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MALTEUROP NORTH AMERICA INC. in 3830 W. GRANT STREET, MILWAUKEE, WI 53215 (NAICS 311213). OSHA activity number 340163955.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Malteurop North America INC. — free Get an email when a new federal OSHA severe-injury report for Malteurop North America INC. is published. One employer, no account, unsubscribe in one click.
Site address
3830 W. GRANT STREET
City
MILWAUKEE
State
WI
ZIP
53215
Mailing
3830 W. GRANT STREET, MILWAUKEE, WI 53215
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311213
Employees
48
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 27, 2015
Penalty
Initial $4,951 · Current $4,500 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    a) The employer failed to ensure that the labeling on the conveyors was accurate in describing the location of the lockout. This exposed employees to amputation hazards from the improper lockout of the electrical energy.
Recent events (3)
  • — F (S) $4500
  • — C (S) $4951
  • — Z (S) $4951

1910.147 C06 I B

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 27, 2015
Abate by
Apr 15, 2015
Penalty
Initial $4,950 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified:    (b) The periodic inspection did not include corrective actions for deviations or inadequacies with the procedures and the information (signs) on the steep conveyors; detailing the location of the electrical disconnect. This exposed employees to amputation hazards from the unexpected energization of the equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $4950
  • — Z (S) $4950

1910.147 C06 II

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 27, 2015
Abate by
Apr 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:    (a) The employer failed to ensure that the certified energy control procedures properly identified the name of the person performing the inspection.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Malteurop North America INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340163955.