BLOOMFIELD, CT ·
OSHA Inspection: RACHAEL'S FOOD CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RACHAEL'S FOOD CORPORATION in 76 GRANBY STREET, BLOOMFIELD, CT 06002 (NAICS 311612). OSHA activity number 340051341.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RACHAEL'S FOOD CORPORATION
- Site address
- 76 GRANBY STREET
- City
- BLOOMFIELD
- State
- CT
- ZIP
- 06002
- Mailing
- 705 MEADOW STREET, CHICOPEE, MA 01013
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 24
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.22 A02
- Issued
- Feb 18, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: A. On or about October 31, 2014: In the following locations, water was allowed to accumulate on the workroom floor: 1. Boiler Room, near a 240V outlet on the aisle side of the Bigelow boiler. 2. Boiler Room, at the back of the Hartford Boiler, near a wall-mounted 2-outlet receptacle with a missing knockout. 3. Compressor Room, near live electrical components on Vilter Screw Compressor #7 and the open door of the Benshaw 208V service disconnect #6.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.147 C04 II B
- Issued
- Feb 18, 2015
- Abate by
- May 18, 2015
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: A. On or about October 31, 2014, facility-wide: The employer had not developed machine-specific lockout procedures for ammonia refrigeration system equipment.
Recent events (2)
- · I (S) $1750
- · Z (S) $3500
1910.147 C06 I
- Issued
- Feb 18, 2015
- Abate by
- May 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A. On or about October 31, 2014, facility-wide: The employer had not conducted inspections of machine-specific energy control procedures within the past year.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C07 I A
- Issued
- Feb 18, 2015
- Abate by
- May 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: A. On or about October 31, 2014, Facility-Wide: Training in the company's lockout/tagout program, including the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control, was not provided to all authorized employees.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G01 II
- Issued
- Feb 18, 2015
- Abate by
- May 18, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A. On or about October 31, 2014, Boiler Room: Access to 208V electrical panels was blocked by the placement of a 26" diameter pedestal fan and a floor-mounted Gardner-Denver compressor. B. Tool Room/Parts Storage Room: A 208V electrical panel was blocked by the storage of wooden boards and a Schumacher 10/40 amp battery charger.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.305 B01 I
- Issued
- Feb 18, 2015
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: A. On or about October 31, 2014, Boiler Room near the entrance to the Tool Room: A wall-mounted 120V outlet box was missing a knockout plug, exposing employees to energized parts. The outlet energized a Black & Decker Heavy Duty Industrial chop saw.
Recent events (2)
- · I (S) $2100
- · Z (S) $4200
1910.305 B02 I
- Issued
- Feb 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: A. On or about October 31, 2014, Compressor Room: At Vilter Screw Compressor #7, a junction box with exposed energized wires was not provided with a cover, exposing employees to electric shock hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 G08
- Issued
- Feb 18, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: On or about October 31, 2014, the employer did not have a material safety data sheet for the anhydrous ammonia used in their refrigeration system.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.1200 H01
- Issued
- Feb 18, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: A. On or about October 31, 2014, facility-wide: Employees had not been provided training in the hazards of anhydrous ammonia.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Rachael'S Food Corporation
View Rachael'S Food Corporation's full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340051341.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.