Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & Z CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & Z CONSTRUCTION LLC in 48ST LOT 18 NW, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 340053131.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & Z Construction LLC — free Get an email when a new federal OSHA severe-injury report for A & Z Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
48ST LOT 18 NW
City
WASHINGTON
State
DC
ZIP
20010
Mailing
15315 BOND MILL RD, LAUREL, MD 20707
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.95 A

Serious Gravity 5 5 instances 5 exposed
Issued
Dec 30, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.   a) On October 1, 2014 and at times prior thereto; throughout site; employees were not wearing eye protection while operating equipment such as but limited to pneumatic nail guns exposing them to a struck by hazard while framing the residential home.
Recent events (1)
  • — Z (S) $1600

1926.501 B13

Serious Gravity 10 4 instances 4 exposed
Issued
Dec 30, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) On October 1, 2014 and at times prior thereto; roof area; employees framing a new residential home were observed walking the trusses and working on the outside wall without a personal fall arrest system in place to prevent them from falling 35 - 40 foot to ground level.
Recent events (1)
  • — Z (S) $2800

1926.1052 C01 II

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 30, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a) On October 1, 2014 and at times prior thereto; stairs west-side of garage; the stairs rising 40 inches used to access the interior of the residential home from the garage was not protected by railing on both open sides exposing employees to a potential fall hazard.
Recent events (1)
  • — Z (S) $1600

1926.1053 B01

Serious Gravity 10 2 instances 4 exposed
Issued
Dec 30, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) On October 1, 2014 and at times prior thereto; second floor west-side; the six foot step ladders used to access the roof area were not tall enough to extend three feet above the working platform exposing them to a 10 foot fall hazard while using the ladder to access the roof or coming down from the roof.
Recent events (1)
  • — Z (S) $2800

1926.1053 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Dec 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step   a) On October 1, 2014 and at times prior thereto; second floor west-side; the six foot step ladders used to access the roof area were not tall enough to extend three feet which resulted in the employees using the top step while accessing the roof area or while stretching from the roof area to access the top of the ladder; exposing employees to a fall hazard of 10 feet to the second floor platform.
Recent events (1)
  • — Z (S) $0

View A & Z Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340053131.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.