Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OZARK MOUNTAIN TECH INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of OZARK MOUNTAIN TECH INC. in 106 MIDLAND DRIVE, CUBA, MO 65453 (NAICS 332813). OSHA activity number 340060789.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ozark Mountain Tech INC. — free Get an email when a new federal OSHA severe-injury report for Ozark Mountain Tech INC. is published. One employer, no account, unsubscribe in one click.
Site address
106 MIDLAND DRIVE
City
CUBA
State
MO
ZIP
65453
Mailing
106 MIDLAND DRIVE, CUBA, MO 65453
Inspection type
Planned (H)
Scope
Records only (C)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
139
Ownership type
A

5 citations on file for this inspection.

1910.146 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2014
Abate by
Jan 20, 2015
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.146(c)(2): If the workplace contained permit spaces, the employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  (NOTE: A sign reading DANGER -- PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language would satisfy the requirement for a sign.)    Permit-required confined spaces at the following locations were not placarded with a suitable sign:    a) Wood boiler in Boiler room  b)  A-B Line Tanks (except rinse tanks)  c) Scrubbers in Tank room  d) Waste Water room Tank
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

1910.146 C05 I C

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 1, 2014
Abate by
Jan 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(5)(i)(C): The employer did not develop monitoring and inspection data that supported the demonstrations required by paragraphs (c)(5)(i)(A) and (c)(5)(i)(B) of this section:  The results of atmospheric testing before authorizing entry into the wood boiler in the boiler room were not recorded.  Forced air ventilation was not installed or used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 F

Deleted Serious Gravity 5 4 instances 3 exposed
Issued
Dec 1, 2014
Abate by
Jan 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(f): The entry permits that documented compliance with this section and authorized entry to a permit space did not identify the following:  a/ The authorized entrant(s). (Permit dated 10/21/2014) b/    The results of initial and periodic tests performed under paragraph (d)(5) of this section, accompanied by the names or  initials of the testers and by an indication of when the tests were performed  (Permit dated 4/13/2014) c/  The rescue and emergency services that can be summoned and the means (such as the equipment to use and the  numbers to call) for summoning those services.  (Permits dated 5/16/2014 and 4/13/2014)  d/   The equipment, such as personal protective equipment, testing equipment, communications equipment, alarm systems,  and rescue equipment, to be provided for compliance with this section.   (Permits dated 5/16/2014 and 4/13/2014)
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 K02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 1, 2014
Abate by
Jan 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(k)(2)(i): The employer did not provide affected employees with the personal protective equipment (PPE) needed to conduct permit space rescues safely and train affected employees so they were proficient in the use of that PPE, at no cost to those employees;  Inside the wood-fueled boiler in the boiler room, appropriate rescue equipment for the entrant in the form of wristlets or equivalent were neither provided nor used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 K02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 1, 2014
Abate by
Jan 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(k)(2)(iv): the employer did not ensure that affected employees practiced making permit space rescues at least once every 12 months, by means of simulated rescue operations in which they removed dummies, manikins, or actual persons from the actual permit spaces or from representative permit spaces:  (Representative permit spaces shall, with respect to opening size, configuration, and accessibility, simulate the types of permit spaces from which rescue is to be performed.)  Annual practice of rescue operations was not performed for the following permit-required confined spaces:  a) Wood boiler in Boiler room b)  A-B Line Tanks (except rinse tanks) c) Scrubbers in Tank room d) Waste Water room Tank
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Ozark Mountain Tech INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340060789.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.