Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONTROL DEVICES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CONTROL DEVICES, LLC in 1555 LARKIN WILLIAMS ROAD, FENTON, MO 63026 (NAICS 331210). OSHA activity number 340065044.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Control Devices, LLC — free Get an email when a new federal OSHA severe-injury report for Control Devices, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1555 LARKIN WILLIAMS ROAD
City
FENTON
State
MO
ZIP
63026
Mailing
1555 LARKIN WILLIAMS ROAD, FENTON, MO 63026
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
260
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II D

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 19, 2015
Abate by
Apr 8, 2015
Penalty
Initial $3,750 · Current $2,625 Reduced
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control:     a) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014, the energy control procedures for the Hydromat Machines did not include instructions on how to verify the effectiveness of the lockout devices.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3750

1910.147 C06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 19, 2015
Abate by
Apr 8, 2015
Penalty
Initial $3,750 · Current $2,625 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014, the employer did not conduct periodic inspections at least annually to ensure that the procedure and the requirements of this standard were being followed.  Energy control procedures specifically for the HydroMat Machines had not been reviewed nor had any of the companys authorized employees performed periodic inspections.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3750

1910.147 C07 I

Serious Gravity 10 1 instance 40 exposed
Issued
Mar 19, 2015
Abate by
Apr 23, 2015
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by authorized, affected, and other employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by authorized employees:   a) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014, machine operators performed service and maintenance work to include, but not limited to machine set-up, unjamming of parts, and tool changes, on the Hydromat Machines. The Hydromat Machines had multiple energy services including hydraulic, electric, and thermal. Operators were not considered authorized employees to conduct lockout tagout. This condition exposed employees to amputation hazards.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.178 A04

Serious Gravity 5 1 instance 20 exposed
Issued
Mar 19, 2015
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.178(a)(4): Capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly when a modification which affected its capacity was performed:    a) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014, the employer installed a 7 foot boom for the Mitsubishi FGC40K forklift which was marked CD001. The altered capacity of the forklift was unknown. Employees utilized the boom for the purpose of lifting and transporting bundles of steel and brass materials in and around the facility. This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.178 Q07

Serious Gravity 5 1 instance 20 exposed
Issued
Mar 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were being placed in services after the examination showed condition(s) adversely affecting the safety of the vehicle:    a) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014, the daily examination for the Mitsubishi Model FGC40K forklift, marked CD001, did not sufficiently recognize adverse conditions which affected the safety of the vehicle. The 7 foot boom was not positively secured to the forklift. This condition exposed employees to struck-by hazards.   b) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014, the daily examination for the Mitsubishi Model FGC40K forklift, marked CD001, did not sufficiently recognize adverse conditions which affected the safety of the vehicle. The load rating for the 7 foot boom was not known. This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 I01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 19, 2015
Penalty
Initial $3,750 · Current $2,625 Reduced
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:    a) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014,  employees in the machine shop area used 2 inch by 5 foot synthetic slings to lift and position hydromat motors during machine set-up and configuration changes. The slings were no longer equipped with load rating tags.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3750

1910.184 D

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.184(d): The employer did not ensure that slings and all fastenings and attachments were inspected for damage and/or defects by a competent person prior to utilization:     a) Control Devices, LLC @ 1555 Larkin Williams Road, Fenton, MO 63026: On and before November 5, 2014,  the employer did not conduct sling inspections prior to the use of slings in the machining area specific to work related to hyrdomat configuration changes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Control Devices, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340065044.