Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WASTE MANAGEMENT OF WISCONSIN, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WASTE MANAGEMENT OF WISCONSIN, INC. in 1715 DELEGLISE STREET, ANTIGO, WI 54409 (NAICS 562111). OSHA activity number 340070853.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Waste Management of Wisconsin, INC. — free Get an email when a new federal OSHA severe-injury report for Waste Management of Wisconsin, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1715 DELEGLISE STREET
City
ANTIGO
State
WI
ZIP
54409
Mailing
1715 DELEGLISE STREET, ANTIGO, WI 54409
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
50
Ownership type
A

9 citations on file for this inspection.

1910.132 C

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Jan 7, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.132(c): Personal protective equipment was not of safe design and construction for the work to be performed:    On and before 8/27/14, maintenance employees were provided uniforms to wear in environments where hot work was to be performed which were not made with 100% cotton or other fire resistant fabric.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.132 D01 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:  On and before 8/27/14, the facility manager did not ensure that the PPE identified by Waste Management's Hazard Assessment was provided to and used by the employees when needed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B02 I B

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.252(b)(2)(i)(B): Goggles or other suitable eye protection were not used during all gas welding or oxygen cutting operations:   On and before 8/27/14, employees using an oxygen and acetylene torch to cut metal were not equipped with goggles with the appropriate shade lenses for the work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B03

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.252(b)(3): Employees exposed to the hazards created by welding, cutting, or brazing operations were not protected by personal protective equipment in accordance with the requirements of 29 CFR 1910.132: (Note:  Appropriate protective clothing required for welding operation will vary with the size, nature and location of the work to be performed.)  On and before 8/27/14, employees performing welding and cutting work were not equipped with fire resistant clothing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 A02 IV

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.252(a)(2)(iv): Cutting or welding was permitted in areas before the areas were inspected by the individual responsible for authorizing cutting and welding operations:    On and before 8/27/14, the employer did not designate and identify a person to be responsible for authorizing hot work or for inspecting the work area before allowing hot work to be performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.252 A02 VI C

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(vi)(C): Cutting or welding was permitted in the presence of explosive atmospheres (mixture of flammable gases, vapors, liquids, or dusts with air), or explosive atmospheres that could develop inside uncleaned or improperly prepared tanks or equipment which had previously contained such materials, or that could develop in areas with an accumulation of combustible dusts:  On and before 8/27/14, mechanics were permitted to perform hot work in areas inside the maintenance shop where flammable or explosive fumes and vapors from fuel, lubricants and other chemicals could build up during normal work activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 A02 XIII

Deleted Serious Gravity 10 3 instances 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(xiii): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment on its property, in accordance with 29 CFR 1910.252 (a)(2)(xiii)(A) through 29 CFR 1910.252(a)(2)(xiii)(D)(a):   On and before 8/27/14, the management did not identify areas within the maintenance shop where hot work could be safely performed, designate an individual to authorize hot work outside of those areas identified, or ensure that the workers and their supervisors were trained to safely use the equipment and to understand the hot work processes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 A03 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.252(a)(3)(i): Welding, cutting, or other hot work was performed on used drums, barrels, tanks, or other containers that had not been cleaned so thoroughly as to make absolutely certain there were no flammable materials present or any substances such as greases, tars, acids, or other materials which where subjected to heat, might produce flammable or toxic vapors:    On 8/27/14, an employee used an oxygen and acetylene torch to cut a piping and pipe fittings leading to a hydraulic reservoir that had not been cleaned to remove all flammable residue and exposed the employee to fire hazard potentials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.132 F01

Deleted Other-than-serious 1 instance 3 exposed
Issued
Dec 8, 2014
Abate by
Dec 22, 2014
Penalty
Initial $1,100 · Current $0 Reduced
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment:   Prior to 8/27/14, all the maintenance employees had not been trained to properly select, inspect, and use all the PPE necessary to perform their duties safely.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1100

View Waste Management of Wisconsin, INC.'s full OSHA safety record →