WASHINGTON, DC —
OSHA Inspection: MOSELEY CONSTRUCTION GROUP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MOSELEY CONSTRUCTION GROUP, INC. in 618 SOUTH CAROLINA AVE., SE, WASHINGTON, DC 20024 (NAICS 236115). OSHA activity number 340071760.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOSELEY CONSTRUCTION GROUP, INC.
- Site address
- 618 SOUTH CAROLINA AVE., SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20024
- Mailing
- 13849 PARK CENTER RD., SUITE A, HERNDON, VA 20171
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.200 C01
- Issued
- Apr 3, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.200(c)(1): Caution signs (see Figure G-2) were not used to warn against potential hazards or to caution against unsafe practices: a) 618 S. Carolina Ave., SE, All Floors - Caution signs were not posted on interior doors which covered elevator shaft openings which could have alerted workers not to open those doors under any circumstances. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (O) $4900
- — Z (S) $4900
1926.501 B13
- Issued
- Apr 3, 2015
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 618 S. Carolina Ave., SE, Third Floor - On or about 11/07/2014, a means of fall protection, including, but not limited to, locking or otherwise restraining a door covering the opening to an elevator shaft, was not provided to a painter who fell 30 feet after opening the door and walking directly into the unguarded shaft.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1926.1052 C01 I
- Issued
- Apr 3, 2015
- Penalty
- Initial $4,200 · Current $4,200
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) 618 S. Carolina Ave., SE, First Floor - On or about 11/07/2014, construction workers were exposed to a 10 foot fall from a stairway which was not provided with a handrail. b) 618 S. Carolina Ave., SE, Second Floor - On or about 11/07/2014, construction workers were exposed to a 10 foot fall from a stairway which was not provided with a handrail.
Recent events (2)
- — I (S) $4200
- — Z (S) $4200
1926.1052 C01 II
- Issued
- Apr 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) 618 S. Carolina Ave., SE, First Floor - On or about 11/07/2014, construction workers were exposed to a 10 foot fall from a stairway which was not provided with a handrail. b) 618 S. Carolina Ave., SE, Second Floor - On or about 11/07/2014, construction workers were exposed to a 10 foot fall from a stairway which was not provided with a handrail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C12
- Issued
- Apr 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part: a) 618 S. Carolina Ave., SE, First Floor - On or about 11/07/2014, construction workers were exposed to a 10 foot fall from the landing of a stairway which was not provided with standard guardrails. b) 618 S. Carolina Ave., SE, Second Floor - On or about 11/07/2014, construction workers were exposed to a 10 foot fall from the landing of a stairway which was not provided with standard guardrails.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Moseley Construction Group, INC.
View Moseley Construction Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340071760.