CINCINNATI, OH ·
OSHA Inspection: MADISON BOWL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MADISON BOWL, INC. in 4761 MADISON RD., CINCINNATI, OH 45227 (NAICS 713950). OSHA activity number 340074582.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MADISON BOWL, INC.
- Site address
- 4761 MADISON RD.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45227
- Mailing
- 4761 MADISON RD., CINCINNATI, OH 45227
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713950
- Employees
- 25
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.23 C03
- Issued
- Mar 11, 2015
- Abate by
- Apr 27, 2015
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards shall be guarded with a standard railing and toe board. a) Employees were exposed to falls into the pin setting equipment while working on the platforms located 5' above the moving pin setting equipment that were not protected with railing and toe boards for each of the 32 lanes of AMF Model 82-70; pin setting machines.
Recent events (2)
- · I (S) $2000
- · Z (S) $2800
1910.147 C01
- Issued
- Mar 11, 2015
- Abate by
- Apr 27, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) The employer did not develop/establish an energy control program consisting of energy control procedures, implement employee training and periodic inspections with respect to the use of lockout in preventing release of unexpected energy such as during the servicing and maintenance including but not limited to retrieving balls or resetting pins for the AMF model #82-70 pin setting machines (32) of them, to protect employees exposed to moving and energized parts.
Recent events (2)
- · I (S) $0
- · Z (S) $2800
1910.219 C02 I
- Issued
- Mar 11, 2015
- Abate by
- Apr 27, 2015
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a) On or about November 7, 2014 while recreating an incident for a news reporter how an injury could occur when you have a jams in the pin setter was not protected from the rotating 18 inch shaft above his head and the 3 inch shaft on the pulley in the middle section, on the AMF #82-70 pinsetters, while retrieving bowling balls and/or retrieving pins. b) Guarding was not in place over the 18 inch shaft above head and the 3 inch shaft on the pulley in the middle section on the (32) thirty two lanes on the AMF #8270 pin setters exposing employees to rotating parts.
Recent events (2)
- · I (S) $2000
- · Z (S) $2800
1910.219 D01
- Issued
- Mar 11, 2015
- Abate by
- Apr 27, 2015
- Penalty
- Initial $1,600 · Current $1,700
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. a) Guarding was not attached over the pinch point created from the rotating belt pulleys located in the rear of the bowling alley, employees retrieving bowling balls and/or resetting pins were exposed to unguarded pulleys driving the ball return mechanisms movement on the AMF #8270 (32) lanes, pin setters front section at the wooden plank step. b) Guarding was not attached over the pinch point created from the rotating belt pulleys located in the rear of the bowling alley, employees retrieving bowling balls and/or resetting pins were exposed to unguarded pulleys top section of the tumbler, driving the ball return mechanisms movement on the AMF #8270 (32) lanes, on the pin setters top portion at the electrical box platform.
Recent events (2)
- · I (S) $1700
- · Z (S) $1600
1910.219 E03 I
- Issued
- Mar 11, 2015
- Abate by
- Apr 27, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. a) On or about November 7, 2014 while recreating an incident for a news reporter, guarding was not in place for the pin setter tumbler belt exposing employees to pinch points. The inclined belt is part of the ball return drive system, employees were exposed while reaching inside of the pin setting machine AMF Model #82-70. b) Guarding was not in place for the 32 lanes of the AMF #8270 pin setters machines tumbler belts front section exposing employees to pinch points. c) Guarding was not in place for the 32 lanes of the AMF #8270 pin setters machine tumbler belts top section exposing employees to pinch points.
Recent events (2)
- · I (S) $0
- · Z (S) $2800
1910.303 G02 I
- Issued
- Mar 11, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a) The AMF #8270 pin setters electrical drive motors wiring operating at greater than 50 volts were not covered and/or enclosed within the motor on lanes 16, 17 and 18 in that the cover places were missing, exposing employees to live electrical contacts. b) The AMF #8270 pin setters main electrical control boxes operating at greater than 50 volts were not covered and/or enclosed within the boxes on all 32 lanes exposing employees to live electrical contacts.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.305 B01 I
- Issued
- Mar 11, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $1,200 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. a) Knockouts on the AMF #8270 pin setters control panels were not enclosed to prevent employees exposure, in that the panel had opening due to missing knockouts.
Recent events (2)
- · I (O) $500
- · Z (S) $1200
More inspections in this industry (NAICS 713950)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340074582.