LINEVILLE, AL —
OSHA Inspection: TRU-WOOD CABINET COMPANY, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TRU-WOOD CABINET COMPANY, LLC in 320 ACE STREET, LINEVILLE, AL 36266 (NAICS 337110). OSHA activity number 340079508.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRU-WOOD CABINET COMPANY, LLC
- Site address
- 320 ACE STREET
- City
- LINEVILLE
- State
- AL
- ZIP
- 36266
- Mailing
- 41778 HIGHWAY 77, ASHLAND, AL 36251
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 53
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 12, 2015
- Abate by
- Mar 20, 2015
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 11/13/14 - Rough Lumber Department, maintenance employees and operators perform servicing and maintenance activities on the Raimann Profirip CNC gang rip machine #14 without utilizing machine specific control of hazardous energy procedures for electrical, hydraulic and pneumatic energy sources: (b) On or about 11/13/14 - Rough Lumber Department, maintenance employees and operators are performing servicing and maintenance activities on the Weinig CNC gang rip machine #15 without utilizing specific control of hazardous energy procedures for electrical and pneumatic energy sources. (c) On or about 11/13/14 - Rough Lumber Department, maintenance employees and operators are performing servicing and maintenance activities on the Powermat 1000 CNC molder machines without utilizing specific control of hazardous energy procedures for electrical, hydraulic and pneumatic energy sources. (d) On or about 11/13/14 -Rough Lumber Department, maintenance employees and operators are performing servicing and maintenance activities on the Friulmac Randomat T-Rex CNC double end machine without utilizing specific control of hazardous energy procedures for electrical and pneumatic energy sources. -
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.212 A01
- Issued
- Mar 12, 2015
- Abate by
- Mar 20, 2015
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 11/13/2014, Rough Lumber Department, the sliding door interlock on the Weining Hydromat 23C Molder Machine #15 had been by-passed to allow the molding machine to operate in normal function with the door guard open.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.303 B07 IV
- Issued
- Mar 12, 2015
- Abate by
- Mar 20, 2015
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: (a) On or about 11/13/14 - Rough Lumber, molder machine #14 disconnect, the 480 volt disconnect has a damaged box and missing control handle.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.303 B02
- Issued
- Mar 12, 2015
- Abate by
- Mar 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about 11/13/14 - Rough Lumber, two re-locatable power taps (RPT) were being used to extend branch circuits of the facility.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Mar 12, 2015
- Abate by
- Mar 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about 11/13/14 , Maintenance shop, unprotected temporary wires to provide electrical service plug to the welding machine.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Tru-Wood Cabinet Company, LLC
View Tru-Wood Cabinet Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340079508.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.