MARIETTA, OH —
OSHA Inspection: SKYE METAL RECOVERY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SKYE METAL RECOVERY, INC. in 217 BLUE KNOB ROAD, MARIETTA, OH 45750 (NAICS 238990). OSHA activity number 340083039.
Where did this inspection happen?
- Establishment
- SKYE METAL RECOVERY, INC.
- Site address
- 217 BLUE KNOB ROAD
- City
- MARIETTA
- State
- OH
- ZIP
- 45750
- Mailing
- 217 BLUE KNOB ROAD, MARIETTA, OH 45750
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.350 A01
- Issued
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.350(a)(1): Valve protection caps shall be in place and secured. a. At the worksite where a compressed gas cylinder of acetylene was stored, the valve protection cap was not in place and secured, thereby exposing employees to a contact or struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.350 A09
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.350(a)(9): Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried. a. At the worksite where compressed gas cylinders were stored, the cylinders were not secured, thereby exposing employees to a struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.350 A10
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a. At the worksite where compressed gas cylinders were stored, the oxygen and acetylene bottles were stored next to each other, thereby exposing employees to a contact hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.350 H
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.350(h): Regulators and gauges. Oxygen and fuel gas pressure regulators, including their related gauges, shall be in proper working order while in use. a. On the portable welding trailer where an oxygen and acetylene torch was in use, the acetylene gauge was damaged, thereby exposing employees to a contact hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.1412 D01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1412(d)(1): A competent person must begin a visual inspection prior to each shift the equipment will be used, which must be completed before or during that shift. The inspection must consist of observation for apparent deficiencies. Taking apart equipment components and booming down is not required as part of this inspection unless the results of the visual inspection or trial operation indicate that further investigation necessitating taking apart equipment components or booming down is needed. Determinations made in conducting the inspection must be reassessed in light of observations made during operation. a. At the worksite where a Drott 1800 crane was used to lift materials in the construction process, a shift inspection was not conducted, thereby exposing the employees to a struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.1412 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1412(e)(1): Each month the equipment is in service it must be inspected in accordance with paragraph (d) of this section (each shift). a. At the worksite where a Drott 1800 crane was used to lift materials in the construction process, an monthly inspection was not conducted, thereby exposing the employees to a struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1412 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1412(f)(1): At least every 12 months the equipment must be inspected by a qualified person in accordance with paragraph (d) of this section (each shift) except that the corrective action set forth in paragraphs (f)(4), (f)(5), and (f)(6) of this section must apply in place of the corrective action required by paragraphs (d)(2) and (d)(3) of this section. a. At the worksite where a Drott 1800 crane was used to lift materials in the construction process, an annual inspection was not conducted, thereby exposing the employees to a struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at SKYE METAL RECOVERY, INC.
MARIETTA, OH—2024-04-24 00:00:00
SKYE METAL RECOVERY, INC.
MARIETTA, OH—2017-06-14 00:00:00
SKYE METAL RECOVERY, INC.
View SKYE METAL RECOVERY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
WOODRUFF, UT—2026-07-16 00:00:00
HANG-M-HIGH CRANE SERVICES-W HAVEN
AMHERST, NY—2026-07-15 00:00:00
WEATHER TIGHT INSTALLATIONS
ZEPHYRHILLS, FL—2026-07-14 00:00:00
PERIMETER SOLUTIONS GROUP FLORIDA, LLC
LOS ANGELES, CA—2026-07-13 00:00:00
SANTA ANA CREEK DEVELOPMENT COMPANY
HAGERSTOWN, MD—2026-07-13 00:00:00
DIGGING & RIGGING, INC.
More inspections in OH
DAYTON, OH—2026-07-17 00:00:00
TEKNOL, INC.
PAYNE, OH—2026-07-16 00:00:00
LIPPERT
SUGARCREEK, OH—2026-07-16 00:00:00
PROVIA
CINCINNATI, OH—2026-07-16 00:00:00
GREENACRES FOUNDATION
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
Source