VIRGINIA BEACH, VA —
OSHA Inspection: MACSONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MACSONS, INC. in JEB LITTLE CREEK 1350 GATOR BLVD. BUILDING 3601, VIRGINIA BEACH, VA 23459 (NAICS 238910). OSHA activity number 340084276.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MACSONS, INC.
- Site address
- JEB LITTLE CREEK 1350 GATOR BLVD. BUILDING 3601
- City
- VIRGINIA BEACH
- State
- VA
- ZIP
- 23459
- Mailing
- P.O. BOX 1770, NORFOLK, VA 23501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 18
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 F06
- Issued
- Dec 17, 2014
- Penalty
- Initial $2,100 · Current $1,365 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a.) JEB Little Creek Building 3601: On or about 11/14/14, the path to ground on the yellow 50' extension cord was not permanent and continuous in that the male attachment plug was missing the ground prong. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1365
- — Z (S) $2100
1926.416 E01
- Issued
- Dec 17, 2014
- Penalty
- Initial $2,100 · Current $1,365 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a.) JEB Little Creek Building 3601: On or about 11/14/14, the outer insulation of a green 100' extension cord used with a portable saw was cut, exposing the employee to the internal copper conductor and an electrical shock hazard. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1365
- — Z (S) $2100
1926.501 B04 II
- Issued
- Dec 17, 2014
- Abate by
- Jan 6, 2015
- Penalty
- Initial $2,100 · Current $1,365 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. a.) JEB Little Creek Building 3601, Section (E): On or about 11/14/14, holes in floors that were greater than two inches in diameter were not provided with covers, as a result employees were exposed to trip hazards. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $1365
- — Z (S) $2100
1926.403 B02
- Issued
- Dec 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a.) JEB Little Creek Building 3601, Section (E): On or about 11/14/14, the employer did not ensure extension cords were used in accordance with the listing and labeling in that two extension cords were daisy chained together to supply power to a portable electric saw. No abatement certification or documentation required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.405 G02 IV
- Issued
- Dec 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief was provided to prevent pull from being directly transmitted to joints or terminal screws: a.) JEB Little Creek Building 3601, Section (E): On or about 11/14/14, a 100' yellow extension used with a portable electric saw was not provided with strain relief protection at the female attachment plug. No abatement certification or documentation required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Macsons, INC.
View Macsons, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340084276.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.