PHILADELPHIA, PA —
OSHA Inspection: DMAC CONSTRUCTION, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DMAC CONSTRUCTION, LLC. in 2028 FEDERAL STREET, PHILADELPHIA, PA 19146 (NAICS 238140). OSHA activity number 340086214.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DMAC CONSTRUCTION, LLC.
- Site address
- 2028 FEDERAL STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19146
- Mailing
- 1230 STEEL ROAD, HAVERTOWN, PA 19083
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 C01
- Issued
- May 7, 2015
- Abate by
- May 13, 2015
- Penalty
- Initial $60,500 · Current $48,400 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) are not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) The employer does not restrain the fabricated frame scaffolding from tipping by guying, tying, bracing or equivalent means. This violation was most recently observed on the front wall of 2028 Federal Street on 07 NOVEMBER 2014 where employees were performing bricklaying operations from a fabricated frame scaffold that was not restrained from tipping by installing guys, ties, and braces. The fabricated frame scaffold was approximately twenty-five (25) feet in height and approximately five (5) feet and two (2) inches in width, thus the height to base ratio is approximately five to one (5:1). To abate this ongoing violation, the employer must require the use of guying, tying, bracing, or equivalent means when the height to base ratio exceeds four to one (4:1) on supported scaffolds. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(c)(1) which was contained in OSHA inspection number 906301, citation number 2, item number 2 and was affirmed as a final order on December 5, 2013 with respect to a workplace located at 274 Leverington Avenue, Philadelphia, PA. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(c)(1), which was contained in OSHA inspection number 895701, citation number 2, item number 2 and was affirmed as a final order on September 26, 2013 with respect to a workplace located at 1201 Latona Street, Philadelphia, PA. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(c)(1), which was contained in OSHA inspection number 314236092, citation number 1, item number 2 and was affirmed as a final order on February 3, 2012 with respect to a workplace located at Broad and Catherine Streets, Philadelphia, PA. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(c)(1), which was contained in OSHA inspection number 314231929, citation number 1, item number 1 and was affirmed as a final order on February 2, 2011 with respect to a workplace located at 211 Brown Street, Philadelphia, PA.
Recent events (3)
- — R (W) $48400
- — C (W) $60500
- — Z (W) $60500
1926.451 E01
- Issued
- May 7, 2015
- Abate by
- May 13, 2015
- Penalty
- Initial $60,500 · Current $48,400 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface is not used: a) The employer does not provide a means of access from one level of the scaffold to another by use of ladders, stair towers, or other acceptable means. This violation was most recently observed at the property 2028 Federal Street, Philadelphia, PA on 07 NOVEMBER 2014 where employees were performing bricklaying operations from a fabricated frame scaffold that had no ladders, stair towers, or other acceptable means of access. The fabricated frame scaffold was approximately twenty-five (25) feet in height and employees were observed climbing the scaffold support structures. To abate this ongoing violation, the employer must require the use of portable ladders, attachable ladders or equivalent means of access. McGee Plastering & Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 906301, citation number 3, item number 1 and was affirmed as a final order on December 5, 2013 with respect to a workplace located at 274 Leverington Avenue, Philadelphia, PA. McGee Plastering & Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 895701, citation number 1, item number 2 and was affirmed as a final order on September 26, 2013 with respect to a workplace located at 12th and Latona Streets, Philadelphia, PA. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 314231929, citation number 2, item number 3a and was affirmed as a final order on February 9, 2011 with respect to a workplace located at 211 Brown Street, Philadelphia, PA. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 314230426, citation number 2, item number 1 and was affirmed as a final order on January 25, 2011 with respect to a workplace located at 224-234 George Street, Philadelphia, PA. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 314230194, citation number 2, item number 1 and was affirmed as a final order on January 25, 2011 with respect to a workplace located at 200 George Street, Philadelphia, PA.
Recent events (3)
- — R (W) $48400
- — C (W) $60500
- — Z (W) $60500
1926.451 F06
- Issued
- May 7, 2015
- Abate by
- May 13, 2015
- Penalty
- Initial $60,500 · Current $48,400 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds are erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): a) The employer does not ensure that scaffolding is erected at the minimum distances set forth by this OSHA standard. This violation was most recently observed on the property 2028 Federal Street, Philadelphia, PA on 07 NOVEMBER 2014 where employees were applying a brick veneer from the tubular welded frame scaffold less than 3 feet from a single phase power line of approximately 120/240 Volts to ground, exposing employees to a shock and/or electrocution hazard. To abate this ongoing violation the employer must ensure that the power lines are de-energized, rerouted, jumped, or, that the scaffolding is erected at least 10 feet from the energized electrical lines. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(f)(6), which was contained in OSHA inspection number 965324, citation number 1, item number 1 and was affirmed as a final order on June 20, 2014 with respect to a workplace located at 1806 West Montgomery Avenue, Philadelphia, PA. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.451(f)(6), which was contained in OSHA inspection number 314230194, citation number 1, item number 2 and was affirmed as a final order on January 25, 2011 with respect to a workplace located at 200 George Street in Philadelphia, PA. McGee Plastering and Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.416(a)(1), which was contained in OSHA inspection number 314236027, citation number 1, item number 2a and was affirmed as a final order on October 19, 2011 with respect to a workplace located at 1917 Mount Vernon Street, Philadelphia, PA.
Recent events (3)
- — R (W) $48400
- — C (W) $60500
- — Z (W) $60500
1910.1200 E01
- Issued
- May 7, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $8,800 · Current $5,800 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) a) The employer does not develop or implement a written hazard communication program. This violation was most recently noted at the property located at 2028 Federal Street, Philadelphia, PA on 07 NOVEMBER 2014 where employees were performing bricklaying operations with Keystone Colored Masonry Cement without a developed or implemented hazard communication program. To abate this ongoing violation, the employer must develop and implement a written hazard communication program describing how the criteria in 29 CFR 1910.1200(f), (g), and (h) will be met. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 906301, citation number 1, item number 1a and was affirmed as a final order on December 5, 2013 with respect to a workplace located at 274 Leverington Avenue, Philadelphia, PA. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 895701, citation number 1, item number 3a and was affirmed as a final order on September 26, 2013 with respect to a workplace located at 1201 Latona Street, Philadelphia, PA.
Recent events (3)
- — R (S) $5800
- — C (R) $8800
- — Z (R) $8800
1910.1200 G08
- Issued
- May 7, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s): (Construction Reference 1926.59) a) The employer does not furnish or maintain copies of the safety data sheets for each chemical in the workplace. This violation was most recently noted at the property of 2028 Federal Street, Philadelphia, PA on 07 NOVEMBER 2014 where employees were performing bricklaying operations and utilizing Keystone Colored Masonry Cement in the course of their duties. To abate this ongoing violation, the employer must maintain copies of each safety data sheet for each chemical used at each jobsite. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 906301, citation number 1, item number 1c and was affirmed as a final order on December 5, 2013 with respect to a workplace located at 274 Leverington Avenue, Philadelphia, PA. McGee Plastering and Stucco Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 895701, citation number 1, item number 3b and was affirmed as a final order on September 26, 2013 with respect to a workplace located at 1201 Latona Street, Philadelphia, PA.
Recent events (3)
- — R (S) $0
- — C (R) $0
- — Z (R) $0
More inspections at Dmac Construction, LLC.