EAST SYRACUSE, NY —
OSHA Inspection: ALLEN TOOL PHOENIX INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALLEN TOOL PHOENIX INCORPORATED in 6821 ELLICOTT DRIVE, EAST SYRACUSE, NY 13057 (NAICS 332710). OSHA activity number 340087386.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLEN TOOL PHOENIX INCORPORATED
- Site address
- 6821 ELLICOTT DRIVE
- City
- EAST SYRACUSE
- State
- NY
- ZIP
- 13057
- Mailing
- 6821 ELLICOTT DRIVE, EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 19
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.101 B
- Issued
- Dec 8, 2014
- Abate by
- Dec 18, 2014
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.101(b): 29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over: a) SMA Area, Welding Area, on or about 11/18/14: An argon cylinder was not secured from being knocked over. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.253 B02 IV
- Issued
- Dec 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) SMA Area, Welding Area, on or about 11/18/14: An argon cylinder was not provided with a valve protection cap.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Dec 8, 2014
- Abate by
- Jan 10, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts and unused portion of bandsaw blade: a) LMA Area, on or about 11/18/14: Rotating chuck and spindle on an Edlund drill press was not guarded. b) LMA Area, on or about 11/18/14: Unused portion of blade on a DoAll horizontal bandsaw was not adequately guarded on the left side. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.305 B01 II
- Issued
- Dec 8, 2014
- Abate by
- Jan 10, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) SMA Area, on or about 11/18/14: A circuit breaker panel labeled P2 had blanks missing exposing live electrical parts. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.147 C06 I
- Issued
- Dec 8, 2014
- Abate by
- Jan 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) At the establishment, on or about 11/18/14: There were no annual inspections conducted of the energy control procedures (lockout/tagout) to ensure that the procedures and requirements were being followed. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Dec 8, 2014
- Abate by
- Jan 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Inspection Lab, on or about 11/18/14: Extension cord providing current to the battery charger for the Micro-Hite machine was strung through an opening in the ceiling and being used as permanent wiring. b) Inspection Lab, on or about 11/18/14: Extension cord and a strip outlet providing current to a permanent affixed light for the Sheffield CMM machine were being used as permanent wiring. c) LMA Area, on or about 11/18/14: A red extension cord wrapped up and attached behind the CNC machine across from the break room was connected to a strip outlet and being used as permanent wiring. Abatement certification must be submitted for these items.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Allen Tool Phoenix Incorporated
View Allen Tool Phoenix Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340087386.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.