EAST SYRACUSE, NY —
OSHA Inspection: ALLEN TOOL PHOENIX INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALLEN TOOL PHOENIX INCORPORATED in 6821 ELLICOTT DRIVE, EAST SYRACUSE, NY 13057 (NAICS 332710). OSHA activity number 343881751.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLEN TOOL PHOENIX INCORPORATED
- Site address
- 6821 ELLICOTT DRIVE
- City
- EAST SYRACUSE
- State
- NY
- ZIP
- 13057
- Mailing
- 6821 ELLICOTT DRIVE, EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 23
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 12, 2019
- Abate by
- Apr 24, 2019
- Penalty
- Initial $2,576 · Current $1,932 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) LMA South Bay, on or about 3/27/19: Rotating spindle ends and nut projections on a Baldor buffing wheel near the Mazak QT200, were not guarded. b) Tool Room, on or about 3/27/19: Rotating spindle end and nut projection on a Rockwell buffing wheel was not guarded on the right side. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1932
- — Z (S) $2576
1910.303 B02
- Issued
- Apr 12, 2019
- Penalty
- Initial $1,932 · Current $1,449 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) LMA South Bay, on or about 3/27/19: A duplex receptacle outlet box with a flexible cord attached, used to power a Jan Fan pedestal fan, next to the Mazak FJV, was not installed or used in accordance with the listing or labeling.
Recent events (2)
- — I (S) $1449
- — Z (S) $1932
1910.304 G05
- Issued
- Apr 12, 2019
- Abate by
- Apr 24, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) LMA North Bay, on or about 3/27/19: A Marley pedestal fan next to the Mazak horizontal was not grounded in that the ground pin was missing from the plug end. b) LMA South Bay, on or about 3/27/19: A Jan Fan pedestal fan next to the Mazak FJV was not grounded in that the ground pin was missing from the plug end. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Allen Tool Phoenix Incorporated