DAYTON, OH ·
OSHA Inspection: WAYNE OVERHEAD DOOR SALES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WAYNE OVERHEAD DOOR SALES, INC. in 2531 NEEDMORE RD., DAYTON, OH 45414 (NAICS 238160). OSHA activity number 340103605.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAYNE OVERHEAD DOOR SALES, INC.
- Site address
- 2531 NEEDMORE RD.
- City
- DAYTON
- State
- OH
- ZIP
- 45414
- Mailing
- 9073 ST. RT. 48, CENTERVILLE, OH 45458
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 11
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.453 B02 V
- Issued
- Jan 9, 2015
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: Workers were observed engaged in commercial construction activities removing and installing a gutter system on an existing tire manufacturing facility. A worker who utilized a Genie S-40, articulating, extensible, boom aerial lift was exposed to potential 20.0 foot fall hazards in that the worker was not attached to the basket or mast.
Recent events (2)
- · I (S) $1500
- · Z (S) $2800
1926.501 B01
- Issued
- Jan 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Workers were observed engaged in commercial construction activities removing and installing a gutter system on an existing tire manufacturing facility. A worker who was removing existing gutters and tossing gutters to ground area was exposed to potential 20.0 foot fall hazards in that the worker was not utilizing a proper fall protection system.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.454 A
- Issued
- Jan 9, 2015
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Workers were observed engaged in commercial construction activities removing an existing gutter system and installing a new gutter system. A worker who utilized a Genie S-40 articulating, extensible, boom aerial lift was exposed to potential 20.0 fall hazards and was not properly trained in proper hazard recognition and fall protection procedures.
Recent events (2)
- · I (S) $1500
- · Z (S) $2800
1926.503 A01
- Issued
- Jan 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Workers were observed engaged in commercial construction activities removing an existing gutter system and installing a new gutter. A worker was exposed to 20.0 foot fall hazards and was not properly trained in proper fall protection criteria.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.404 B01 I
- Issued
- Jan 9, 2015
- Penalty
- Initial $2,000 · Current $800 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. Located along the side area of an existing manufacturing facility, workers were engaged in commercial construction activities removing an existing gutter system and installing a new gutter system. The Grover gutter machine and DeWalt cutoff saw operator was exposed to electrocution hazards in that the electrical service provided was connected with a 100.0 orange extension cord plugged into a receptacle that was not GFCI protected and an assured equipment grounding program was not in use.
Recent events (2)
- · I (S) $800
- · Z (S) $2000
More inspections at Wayne Overhead Door Sales, INC.
View Wayne Overhead Door Sales, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340103605.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.