Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRIEL PLASTERING & STUCCO, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FRIEL PLASTERING & STUCCO, INC. in 2031 ABIGAIL STREET, PHILADELPHIA, PA 19125 (NAICS 238140). OSHA activity number 340115146.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Friel Plastering & Stucco, INC. — free Get an email when a new federal OSHA severe-injury report for Friel Plastering & Stucco, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2031 ABIGAIL STREET
City
PHILADELPHIA
State
PA
ZIP
19125
Mailing
30 RALSTON AVENUE, HAVERTOWN, PA 19083
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
May 19, 2015
Abate by
May 26, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.      a) At the jobsite: 2031 Abigail Street - Employees engaged in stucco operations from the 5th level of the fabricated frame scaffold were exposed to fall hazards of approximately thirty-five (35) feet without the use of personal fall arrest systems or guardrail systems.  Observed on or about 11/20/2014.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.454 A

Serious Gravity 5 1 instance 3 exposed
Issued
May 19, 2015
Abate by
May 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.   a) At the jobsite: 2031 Abigail Street - Employees working on a fabricated frame scaffold were not trained by a person qualified to recognize, control, or minimize hazards associated with fabricated frame scaffolding. Observed on or about 11/20/14.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
May 19, 2015
Abate by
May 26, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.      a) At the jobsite: 2031 Abigail Street - Employees were not provided with a safe means of access and/or egress to a fabricated frame scaffold platform, exposing employees to a fall hazard of approximately thirty-five (35) feet.  Employees were using the side frame of the scaffold to access and/or egress the working levels.  Observed on or about 11/20/2014.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.451 C01 II

Serious Gravity 10 1 instance 2 exposed
Issued
May 19, 2015
Abate by
May 26, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.451(c)(1)(ii): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by installing guys, ties, and braces according to the manufacturer's recommendations:      a) At the jobsite: 2031 Abigail Street - A fabricated frame scaffold with a height to base ratio of more than four to one (4:1) was not restrained from tipping by guying, tying or bracing.  Employees were applying stucco on the 5th working level, approximately thirty-five (35) feet above ground level.  Observed on or about 11/20/2015.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

View Friel Plastering & Stucco, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340115146.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.