EDISON, NJ —
OSHA Inspection: J & M FUTON COVERS CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J & M FUTON COVERS CORPORATION in 44 NATIONAL ROAD, EDISON, NJ 08817 (NAICS 493110). OSHA activity number 340116169.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & M FUTON COVERS CORPORATION
- Site address
- 44 NATIONAL ROAD
- City
- EDISON
- State
- NJ
- ZIP
- 08817
- Mailing
- 44 NATIONAL ROAD, EDISON, NJ 08817
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 8
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.37 A03
- Issued
- Jan 14, 2015
- Abate by
- Jan 27, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not continuously maintained free of obstructions or impediments to full instant use in the case of fire or other emergency: a/ J & M Futon/Edison NJ Site: Warehouse. Exit doors were blocked by boxes of product, cardboard boxes of miscellaneous and other material, preventing free escape from the facility in the event of a fire or other emergency (including but not limited to) Warehouse Shipping/Receiving Dock Area. 1/ Exit door located on the left side of the Shipping/Receiving Dock towards the office was blocked by cardboard boxes of product. 2/ Exit door on the right side of the Shipping/Receiving Dock leading to the yard/empty Propane storage cage was blocked by cardboard boxes of miscellaneous and other material. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (S) $2800
1910.110 F02 II
- Issued
- Jan 14, 2015
- Abate by
- Jan 27, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.110(f)(2)(ii): LP gas container(s) stored inside were located near or in area(s) normally used or intended for the safe exit of employees: a/ J & M Futon/Edison NJ Site: Warehouse Shipping/Receiving Dock. The staging area for 6 Propane tanks used to power forklift trucks(s) was at the staging area of the Dock where employees travel to reach two exits leading out of the building. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (S) $1200
1910.151 C
- Issued
- Jan 14, 2015
- Abate by
- Jan 27, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a/ J & M Futon/Edison NJ Site: Warehouse Powered Industrial Truck Maintenance Area. An eyewash facility was not provided where battery fluid levels are checked. Eyewash to have 15 minutes continuous flow capacity. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (S) $1600
1910.176 A
- Issued
- Jan 14, 2015
- Abate by
- Jan 27, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.176(a): Aisle(s) or passageway(s) were not kept clear where mechanical handling equipment was used: a/ J & M Futon/Edison NJ Site: Warehouse. Aisles throughout the warehouse were blocked by powered industrial truck equipment, empty corrugated boxes, boxes of product, wooden pallets, metal hand carts, futons and mattress/frames - including but not limited to. Aisles were not maintained free of storage and powered industrial truck equipment in the event of a fire or other emergency. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (S) $2800
1910.178 L04 III
- Issued
- Jan 14, 2015
- Abate by
- Feb 10, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.178(l)(4)(iii): The employer did not ensure that an evaluation of each powered industrial truck operator's performance was conducted at least once every three years: a/ J & M Futon/Edison NJ Site: Warehouse. Forklift operators were not provided an evaluation of forklift training in more than 3 years. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (S) $2800
1910.178 M03
- Issued
- Jan 14, 2015
- Abate by
- Feb 10, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.178(m)(3): A safe place to ride was not provided where riding a powered industrial truck(s) was authorized. a/ J & M Futon/Edison NJ Site: Warehouse (Area adjacent to Shipping/Receiving Dock). An employee was elevated by a forklift operator using a powered industrial truck with a wooden pallet attached to the forklift blades. The employee was standing on the pallet while elevated approx. 8 from the floor (storage rack tier 2 level) without personal fall protection, or an approved cage and without the pallet being secured to the powered industrial truck. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (S) $2800
1910.305 A02 I
- Issued
- Jan 14, 2015
- Abate by
- Feb 10, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting rated 600 volts, nominal, or less were used for purposes other than those permitted in subparagraph's (a), (b), and (c) of this paragraph 1910.305(a): a/ J & M Futon/Edison NJ Site: Warehouse/Employee Lunch Room. General Electric refrigerator and Portable Heater (radiator type - no markings) were powered by extension cord and power strip connections. Temporary wiring was used in lieu of permanent in that the plug did not go directly into a permanent outlet. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (S) $1200
1910.22 A01
- Issued
- Jan 14, 2015
- Abate by
- Jan 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): Places of employment were not kept clean. a/J & M Futon/Edison NJ Site: Warehouse. Aisles and walking areas were not maintained free of paper, cardboard, plastic straps and other debris. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (O) $0
1910.141 D02 II
- Issued
- Jan 14, 2015
- Abate by
- Jan 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Each lavatory was not provided with hot and cold running water, or tepid running water. a/ J & M Futon/Edison NJ Site: Warehouse. Lady's and Men's bathrooms were not provided with hot water, in that the hot water faucet was not in operating condition and/or not turned on for use. Observed on/or about 12/04/2014.
Recent events (1)
- — Z (O) $0
More inspections at J & M Futon Covers Corporation
View J & M Futon Covers Corporation's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340116169.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.