Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: BALFOUR CHERRYWOOD VILLAGE LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BALFOUR CHERRYWOOD VILLAGE LLC in 282 MCCASLIN BLVD, LOUISVILLE, CO 80027 (NAICS 623110). OSHA activity number 340116490.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Balfour Cherrywood Village LLC for free Get an email when a new federal OSHA severe-injury report for Balfour Cherrywood Village LLC is published. One employer, no account, unsubscribe in one click.
Site address
282 MCCASLIN BLVD
City
LOUISVILLE
State
CO
ZIP
80027
Mailing
282 MCCASLIN BLVD, LOUISVILLE, CO 80027
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
68
Ownership type
Private (A)

4 citations on file for this inspection.

1910.305 A02 X

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 2, 2015
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage:    (a)Balfour Cherrywood Village LLC, at 282 McCaslin Boulevard, Louisivlle, CO:  On and before 12/4/14, Balfour Cherrywood Village LLC did not protect flexible cords and cables from accidental damage.  The two flexible cords supplying 120 volt power to two Carter Hoffmann "hotboxes" model BB96-85 in the kitchen were damaged.  The conductors for each power cord were exposed.  This condition exposed employees to an electrical hazard.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.305 G02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 2, 2015
Abate by
Apr 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a)Balfour Cherrywood Village LLC, at 282 McCaslin Boulevard, Louisivlle, CO:  On and before 12/4/14, Balfour Cherrywood Village LLC did not ensure that flexible cords were connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  Two flexible cords supplied 120 volt power to two Carter Hoffmann "hotboxes" model BB96-85 in the kitchen.  Strain relief had not been provided to either power cord at the fitting where each cord entered the hotbox or at the receptacle that each cord was plugged into.  This condition exposed employees to an electrical hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1030 G02 VII F

Repeat Gravity 1 1 instance 5 exposed
Issued
Mar 2, 2015
Penalty
Initial $4,200 · Current $2,940 Reduced
29 CFR 1910.1030(g)(2)(vii)(F): The bloodborne pathogens training program did not contain an explanation of the use or limitations of methods that would prevent or reduce exposure including appropriate engineering controls, work practices or personal protective equipment:    (a)Balfour Cherrywood Village LLC, at 282 McCaslin Boulevard, Louisivlle, CO:  On and preceding 12/4/14, Balfour Cherrywood Village LLC did not ensure that the bloodborne pathogens training program contained an explanation of the use or limitations of methods that would prevent or reduce exposure including appropriate engineering controls, work practices or personal protective equipment.  Nurses used Ultimed Inc UltiCare tuberculin syringes and Retractable Technologies VanishPoint syringes during healthcare duties at the assisted living facility.  The bloodborne pathogens training program did not include an explanation of the use and limitations of medical devices used by nurses.  This condition exposed employees to a bloodborne pathogen hazard.    Balfour Cherrywood Village LLC, was previously cited for a violation of this Occupational Safety and Health Administration Standard or its equivalent standard, 29 CFR 1910.1030(g)(2)(vii)(F), which was contained in OSHA inspection 108781, Citation 1, Item 4 and was issued on December 9, 2011, and affirmed as a final order on January 3, 2012, with respect to a workplace located at 282 McCaslin Boulevard, Louisville, CO.
Recent events (2)
  • · I (R) $2940
  • · Z (R) $4200

1910.1030 C01 IV B

Other-than-serious 1 instance 5 exposed
Issued
Mar 2, 2015
Abate by
Apr 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(iv)(B): The annual review and update of the Exposure Control Plan did not include annual consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure:  (a)Balfour Cherrywood Village LLC, at 282 McCaslin Boulevard, Louisivlle, CO:  On and preceding 12/4/14, Balfour Cherrywood Village LLC did not ensure that the annual review and update of the Exposure Control Plan included annual consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure.  Nurses, caregivers, and housekeepers cared for residents of a long term assisted living facility.  Employees were occupationally exposed to blood or other potentially infectious materials (OPIM).  Nurses used Ultimed Inc UltiCare tuberculin syringes and Retractable Technologies VanishPoint syringes during healthcare duties at the assisted living facility.  The review of the Exposure Control Plan did not include review of medical devices, including syringes, used by nurses.  This condition potentially exposed employees to a bloodborne pathogen hazard.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Balfour Cherrywood Village LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340116490.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.