Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRADKEN ENGINEERED PRODUCTS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BRADKEN ENGINEERED PRODUCTS in 400 S. 4TH ST., ATCHISON, KS 66002 (NAICS 331513). OSHA activity number 340117019.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bradken Engineered Products — free Get an email when a new federal OSHA severe-injury report for Bradken Engineered Products is published. One employer, no account, unsubscribe in one click.
Site address
400 S. 4TH ST.
City
ATCHISON
State
KS
ZIP
66002
Mailing
P.O. BOX 188, ATCHISON, KS 66002
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331513
Employees
415
Ownership type
A

4 citations on file for this inspection.

1910.23 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 5, 2015
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board:  An employee was exposed to injury from a fall onto the moving casting and mold debris on the shaker table. Standard railing was not provided to prevent a fall from the elevated work platform onto the shaker table.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $3400

1910.305 B02 I

Other-than-serious 1 instance 51 exposed
Issued
Mar 5, 2015
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    Employees were exposed to a 110 VAC electrical shock hazard in that the faceplate was missing on the junction box located at column 28 in the no-bake foundry.
Recent events (2)
  • — I (O) $2550
  • — Z (S) $3400

1910.305 G02 III

Other-than-serious 2 instances 50 exposed
Issued
Mar 5, 2015
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    Employees working in the maintenance area were exposed to electrical shock hazards in that flexible cords were not equipped with strain relief on the following equipment:        a)   On the Jet band saw motor.        b)  On plug end of the flexible cord providing 110 VAC power to the Jet 8 inch grinder.
Recent events (2)
  • — I (O) $2550
  • — Z (S) $3400

1910.1200 F09

Other-than-serious 1 instance 2 exposed
Issued
Mar 5, 2015
Abate by
Mar 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(9): The employer did not ensure that labels or other forms of warning were legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift:  The label on the 55 gallon drum of grease, located in the Transportation area, was not legible and was not visible, on the side of the drum against the wall.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bradken Engineered Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340117019.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.