JBER, AK —
OSHA Inspection: AIR NATIONAL GUARD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AIR NATIONAL GUARD in 212TH RQS, JBER, AK 99506 (NAICS 928110). OSHA activity number 340119312.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIR NATIONAL GUARD
- Site address
- 212TH RQS
- City
- JBER
- State
- AK
- ZIP
- 99506
- Mailing
- 176TH WING 17441 AIRLIFTER DRIVE, JBER, AK 99506
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 309
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.212 B
- Issued
- Dec 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. Bldg 177440, Room 105, CBT ARMS: On or about 2 December 2014 and times prior thereto, the 6-inch Porter Cable Bench grinder, Serial number 029627 was not secured to the work bench. This condition exposed employees to struck by hazards.
Recent events (1)
- — Z (S) $0
1910.215 A04
- Issued
- Dec 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch. Bldg 177440, Room 105, CBT ARMS: On or about 2 December 2014 and times prior thereto, the 6-inch Porter Cable Bench grinder, Serial number 029627, work rest measured 1/4 inch from wheel surface. This condition exposed employees to caught in and struck by hazards.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Dec 15, 2014
- Abate by
- Jan 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. Bldg 177440, Parachute shop: On or about 2 December 2014 and times prior thereto, a Fellows brand 120 volt relocatable power tap was connected in series with another relocatable power tap to the sewing machines on the south wall.
Recent events (1)
- — Z (S) $0
1910.305 A02 X
- Issued
- Dec 15, 2014
- Abate by
- Jan 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. Bldg 177440, Room 106, Life Support: On or about 2 December 2014 and times prior thereto, a relocatable power strip was routed through metal shelving. This condition exposed employees to an electrical shock and burn hazard.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Dec 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. Bldg 177440, Room 129, Raft Repair Room: On or about 2 December 2014 and times prior thereto, a blue extension cord was used in lieu of fixed wiring to supply power to the sewing machine. This condition exposed employees to an electrical shock and burn hazard.
Recent events (1)
- — Z (S) $0
More inspections at AIR National Guard
View AIR National Guard's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340119312.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.