CRESTON, NE —
OSHA Inspection: COOPERATIVE SUPPLY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COOPERATIVE SUPPLY, INC. in SW CORNER OF MERIDIAN & 1ST STREET, CRESTON, NE 68631 (NAICS 424510). OSHA activity number 340119346.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COOPERATIVE SUPPLY, INC.
- Site address
- SW CORNER OF MERIDIAN & 1ST STREET
- City
- CRESTON
- State
- NE
- ZIP
- 68631
- Mailing
- PO BOX 278, DODGE, NE 68633
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 14
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 C02
- Issued
- Mar 23, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $3,500 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.23(c)(2): Runways four feet or more above floor or ground level were not guarded by standard railings (or the equivalent): The employer is failing to protect employees working at the leased elevator site location of 1st Street, Creston, NE 68631 from fall hazards of 30 feet in that; the runway above the east row of grain bins was not equipped with a standard railing system consisting of an intermediate rails. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $2500
- — Z (S) $3500
1910.272 J01
- Issued
- Mar 23, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $3,850 · Current $2,500 Reduced
E200
General-duty citation text
29 CFR 1910.272(j)(1): The employer did not develop and implement a written housekeeping program that established the frequency and the method(s) determined best to reduce accumulations of fugitive grain dust on ledges, floors, equipment, and other exposed surfaces. The employer is failing to protect employees working at the leased elevator site location of 1st Street, Creston, NE 68631 from fire and explosion hazards resulting from accumulations of up to a 1/2 inch of combustible dust within the elevator leg control room in that; the employer did not implement the written housekeeping program that was developed by the company at the leased site located at 1st Street, Creston, NE 68631. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $2500
- — Z (S) $3850
1910.307 C02 I
- Issued
- Mar 23, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $3,850 · Current $0 Reduced
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present: The employer is failing to protect employees working at the leased elevator site location of 1st Street, Creston, NE 68631 from fire and explosion hazards in that; the electrical equipment within the leg control room was not approved for the Class 2 Division 1 location where up to 1/2 inch of combustible dust was present. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.
Recent events (2)
- — I (S) $0
- — Z (S) $3850
1910.219 D01
- Issued
- Mar 23, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $6,160 · Current $3,680 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): The employer is failing to protect employees working at the leased elevator site location of 1st Street, Creston, NE 68631 from entanglement hazards in that; the guards on the screw auger drive pulleys did not fully enclose the pulleys that were located within 32 inches of the ground between the grain storage bins. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations. The Cooperative Supply Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.219(d)(1), which was contained in OSHA inspection number 314061409, citation number 1, item number 8a and was affirmed as a final order on August 18, 2011, with respect to a workplace located at 239 Front St, Dodge, NE 68633.
Recent events (2)
- — I (S) $3680
- — Z (R) $6160
1910.219 E03 I
- Issued
- Mar 23, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): The employer is failing to protect employees working at the leased elevator site location of 1st Street, Creston, NE 68631 from entanglement hazards in that; the guards on the screw auger drive belts did not fully enclose the inclined belts that were located within 32 inches of the ground between the grain storage bins. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations. The Cooperative Supply Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 314061409, citation number 1, item number 8b and was affirmed as a final order on August 18, 2011, with respect to a workplace located at 239 Front St, Dodge, NE 68633.
Recent events (2)
- — I (S) $0
- — Z (R) $0
More inspections at Cooperative Supply, INC.
View Cooperative Supply, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340119346.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.