OSHA Inspection: DEFENSE COMMISSARY AGENCY-MOFFETT FIELD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEFENSE COMMISSARY AGENCY-MOFFETT FIELD in BLDG 12, N. AKRON ROAD, MOUNTAIN VIEW, CA 94035 (NAICS 493110). OSHA activity number 340125350.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Defense Commissary Agency-Moffett Field for free Get an email when a new federal OSHA severe-injury report for Defense Commissary Agency-Moffett Field is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 12, N. AKRON ROAD
City
MOUNTAIN VIEW
State
CA
ZIP
94035
Mailing
BLDG 12, N. AKRON ROAD, MOUNTAIN VIEW, CA 94035
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
52
Ownership type
Federal government (D)

7 citations on file for this inspection.

1910.36 B01

Serious Gravity 1 1 instance 30 exposed
Issued
Jan 29, 2015
Abate by
Mar 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(b)(1): At least two exit routes were not available in a workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section:  In the warehouse: At least two exit routes were not available in a L-shaped section of a warehouse that was about 166 feet long by 111 feet wide at the south end and 63 feet wide at the north end.  The only exit door was located near the southeast corner of the warehouse.  The other side hinged doors located near the north side of the warehouse were marked not an exit and locked.  Up to 30 employees that can work in the warehouse were exposed to the hazard of fire.
Recent events (1)
  • · Z (S) $0

1910.36 D01

Serious Gravity 1 1 instance 30 exposed
Issued
Jan 29, 2015
Abate by
Mar 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors:  In the warehouse: Employees cannot open the exit door, near the southeast corner of a L-shaped section of a warehouse, without keys or special knowledge.  The door can be locked on the exterior side with a padlock and chain.  The door mechanism on the interior of the door required special knowledge to operate as it needed to be lifted and slid to one side.  There was no panic bar on the door.   Up to 30 employees that can work in the warehouse were exposed to the hazard of fire.
Recent events (1)
  • · Z (S) $0

1910.157 G01

Serious Gravity 1 1 instance 52 exposed
Issued
Jan 29, 2015
Abate by
Mar 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): Where the employer had provided portable fire extinguishers for employee use in the workplace, the employer did not also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting:      At the commissary, the employer did not provide an educational program on the general principles of fire extinguisher use and the hazards of incipient stage firefighting.  Employees were expected to use the fire extinguishers on incipient stage fires.  Employees were exposed to the hazards of fire.
Recent events (1)
  • · Z (S) $0

1910.305 A02 X

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:  At the rear of the commissary, near the entrance to the meat cutting area: An extension cord was not protected from damage as it laid on the floor between the door frame and the swinging doors to the meat cutting area.  The cord supplied power to a 110 VAC box freezer used to display frozen meats.  Employees were exposed to the hazards of contacting electricity.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:  At the rear of the commissary, near the entrance to the meat cutting area: An extension cord was used to power a 110 VAC box freezer used to display frozen meats.  Employees were exposed to the hazards of contacting electricity.
Recent events (1)
  • · Z (S) $0

1910.305 G02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were not repaired, if spliced, so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced:  At the rear of the commissary, near the entrance to the meat cutting area: An extension cord splice was not repaired properly as the splice was covered with duct tape.  The cord was used to power a 110 VAC box freezer used to display frozen meats.  Employees were exposed to the hazards of contacting electricity.
Recent events (1)
  • · Z (S) $0

1960.8 A

Repeat Gravity 5 4 instances 6 exposed
Issued
Jan 29, 2015
Abate by
Mar 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1960.8 (a): The head of each agency did not furnish to each employee employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being locked into walk-in freezers:    (a) The walk-in freezer for frozen chickens next to the meat cutting area: Handle and rod mechanisms were installed on the exterior of three freezer doors that were about 4.5 feet wide by 6.66 feet high.  The mechanisms can be turned to insert the rods into eye bolts located on the freezers exterior.  The door mechanisms that allowed the doors to be opened from the interior were defeated by the handle and rod mechanisms.  Employees were exposed to the hazard of being locked into a walk-in freezer that was about 7 feet high by 12 feet wide by 12 feet long at a temperature of about 22 degrees Fahrenheit.      Among other methods, one feasible and acceptable method to correct this hazard is to:     Remove the handle and rod mechanisms and eyebolts and ensure door handle mechanisms are installed that comply with NSF/ANSI International Standard for Food Equipment - Commercial refrigerators and freezers (NSF/ANSI 7 ? 2009).  NSF/ANSI 7 ? 2009 requires that walk-in and roll-in refrigerator and freezer doors shall be capable of being opened from the inside, even when locked.  (b) The walk-in freezer to chill meat next to the meat cutting area: The mechanisms to open two 3.5 foot by 6.5 foot freezer doors to the meat cutting area were installed incorrectly.  The door mechanisms that allowed the doors to be opened when locked were installed on the meat cutting area side of the door instead of the walk-in freezer side of the door.    In addition, a handle and rod mechanism was installed on the meat cutting area side on one freezer door.  The mechanisms can be turned to insert the rods into eye bolts located on the meat cutting side of the freezer exterior.    A padlock and chains were installed on the meat cutting area side of the other freezer door.    Employees were exposed to the hazard of being locked into a walk-in freezer that was about 9.5 feet high by 30 feet wide by 36 feet long at a temperature of about 36 degrees Fahrenheit.    Among other methods, one feasible and acceptable method to correct this hazard is to:     Change the door mechanisms that allow the door to be opened when locked to the walk-in freezer side of the door instead of the meat cutting area side of the door; remove the handle and rod mechanisms and eyebolts; remove the padlock and chains; and ensure door handle mechanisms are installed that comply with NSF/ANSI International Standard for Food Equipment - Commercial refrigerators and freezers (NSF/ANSI 7 ? 2009).  NSF/ANSI 7 ? 2009 requires that walk-in and roll-in refrigerator and freezer doors shall be capable of being opened from the inside, even when locked.  (c) The walk-in freezer to chill meat next to the meat cutting area: The 5 foot wide by 7 foot high door to the loading dock area had chains and a padlock on the loading dock side.  The door mechanism that allowed the door to be opened from the interior can be defeated by padlock and chains.  Employees were exposed to the hazard of being locked into a walk-in freezer that was about 9.5 feet high by 30 feet wide by 36 feet long at a temperature of about 36 degrees Fahrenheit.  Among other methods, one feasible and acceptable method to correct this hazard is to:     Remove the chains and padlock from the door and ensure door handle mechanisms are installed that comply with NSF/ANSI International Standard for Food Equipment - Commercial refrigerators and freezers (NSF/ANSI 7 ? 2009).  NSF/ANSI 7 ? 2009 requires that walk-in and roll-in refrigerator and freezer doors shall be capable of being opened from the inside, even when locked.  (d) The Stay Gold Mfg., Inc., walk-in freezer, model number F, serial number 62-519, at the rear of the commissary: Chains and padlocks were installed on the exterior of two freezer doors that were about 3.33 feet wide by 7 feet high.  The freezer doors led to the loading dock area.  The door mechanisms that allowed the doors to be opened from the interior can be defeated by padlocks and chains.  Employees were exposed to the hazard of being locked into a walk-in freezer that was about 7 feet high by 18 feet wide by 40 feet long at a temperature of about 8 degrees Fahrenheit.    Among other methods, one feasible and acceptable method to correct this hazard is to:     Remove the chains and padlocks from the doors and ensure door handle mechanisms are installed that comply with NSF/ANSI International Standard for Food Equipment - Commercial refrigerators and freezers (NSF/ANSI 7 ? 2009).  NSF/ANSI 7 ? 2009 requires that walk-in and roll-in refrigerator and freezer doors shall be capable of being opened from the inside, even when locked.  THE DEFENSE COMMISSARY AGENCY WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1960.8(A) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 980306, CITATION NUMBER 1, ITEM NUMBER 5, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 4, 2014, WITH RESPECT TO A WORKPLACE LOCATED AT BUILDING S-182 APACHE ROAD, FORT HUNTER LIGGETT, CALIFORNIA.
Recent events (1)
  • · Z (R) $0