Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: U.S. DEPARTMENT OF THE AIR FORCE WARNER ROBINS AFB

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of U.S. DEPARTMENT OF THE AIR FORCE WARNER ROBINS AFB in 215 PAGE ROAD SUITE 113, ROBINS A F B, GA 31098 (NAICS 928110). OSHA activity number 340128180.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of the AIR Force Warner Robins AFB for free Get an email when a new federal OSHA severe-injury report for U.S. Department of the AIR Force Warner Robins AFB is published. One employer, no account, unsubscribe in one click.
Site address
215 PAGE ROAD SUITE 113
City
ROBINS A F B
State
GA
ZIP
31098
Mailing
215 PAGE ROAD SUITE 113, ROBINS A F B, GA 31098
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
30
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.36 C01

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Apr 24, 2015
Abate by
Jun 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(c)(1): Each exit discharge did not lead directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside.  On or about December 10, 2014:  Employees performing wastewater treatment operations in the basement of the dipping and coating building were exposed to hazardous liquids including but not limited to chromic acid, cyanide, sulfuric acid, and others.  The door labeled an exit did not discharge directly outside or to an open space with access to the outside.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.124 H04

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 24, 2015
Abate by
Aug 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.124(h)(4): Employees working with chromic acid were not provided with periodic examinations of their exposed body parts, especially their nostrils:  On or about December 10, 2014:  Employees in the basement of the dipping and coating building worked with chromic acid.  The employees were not provided periodic examinations of their body parts and nostrils.  OR   In the alternative:  29 CFR 1910.1026(k)(1)(i)(C)  On or about December 10, 2014:  Employees in the basement of the dipping and coating building were exposed to an emergency spill containing hexavalent chromium.  The employees were not provided an examination of their body parts and nostrils.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.124 J02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2015
Abate by
Aug 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.124(j)(2)(ii): The employer did not ensure airflow was adequate prior to operation after a prolonged shutdown:    On or about December 10, 2014:    Employees performing wastewater treatment operations in the basement of the dipping and coating building were exposed to an unidentified release of a chemical or chemical mixture due to the ventilation system being taken out of service for maintenance.  The employer failed to ensure the airflow was adequate prior to employees returning to work.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 A02

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 24, 2015
Abate by
Aug 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees would not have to travel toward a high hazard area, unless the path of travel was effectively shielded from the high hazard area by suitable partitions or other physical barriers:    On or about December 10, 2014:    Employees performing wastewater treatment operations in the basement of the dipping and coating building were exposed to hazardous liquids including but not limited to chromic acid, cyanide, sulfuric acid, and others.  The exit route causes employees to travel toward an area where chemical hazards exist.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View U.S. Department of the AIR Force Warner Robins AFB's full OSHA safety record →