Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SHORELINE FOUNDATION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SHORELINE FOUNDATION, INC. in 1 EAST 11TH STREET - SLIP 3, RIVIERA BEACH, FL 33404 (NAICS 238110). OSHA activity number 340150564.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shoreline Foundation, INC. — free Get an email when a new federal OSHA severe-injury report for Shoreline Foundation, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 EAST 11TH STREET - SLIP 3
City
RIVIERA BEACH
State
FL
ZIP
33404
Mailing
2781 SW 56TH AVENUE, PEMBROKE PARK, FL 33023
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
102
Ownership type
A

20 citations on file for this inspection.

1910.410 A01

Other-than-serious 1 instance 1 exposed
Issued
Jun 3, 2015
Abate by
Jun 22, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.410(a)(1): Each dive team member did not have the experience or training necessary to perform assigned tasks in a safe and healthful manner, is applicable to the Construction Standard 29 CFR 1926.1071 which incorporates the General Industry Requirements:    On or about February 4, 2015, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not ensure employees who were performing underwater dive operations were experienced or trained in order to perform the assigned task in a safe and healthful manner.
Recent events (3)
  • — R (O) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.410 A03

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2015
Abate by
Jun 22, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.410(a)(3): All dive team members were not trained in cardiopulmonary resuscitation and first aid (American Red Cross standard course or equivalent) is applicable to the Construction Standard 29 CFR 1926.1071 which incorporates the General Industry Requirements:  On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not provide members of a dive team who were engaged in underwater diving operation with cardiopulmonary resuscitation training and first aid (American Red Cross standard course or equivalent).
Recent events (3)
  • — J (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.421 C01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jun 3, 2015
Abate by
Jun 15, 2015
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.421(c)(1): A first aid kit appropriate for the diving operation and approved by a physician was not available at the dive location, is applicable to the Construction Standard 29 CFR 1926.1081 which incorporates the General Industry Requirements:  On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not ensure the first aid kit, was approved by a physician and appropriate for the underwater diving operation conducted at the dive location.
Recent events (3)
  • — J (S) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.421 C03

Other-than-serious 1 instance 4 exposed
Issued
Jun 3, 2015
Abate by
Jun 15, 2015
Penalty
Initial $0 · Current $7,000
29 CFR 1910.421(c)(3): A bag-type manual resuscitator with transparent mask and tubing was not available at the dive location,  is applicable to the Construction Standard 29 CFR 1926.1081 which incorporates the General Industry Requirements:    On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida, 33404, the employer did not provide employees who were performing underwater dive operation a first aid handbook or equivalent, and a bag-type manual resuscitator with a transparent mask and tubing available at the dive location.
Recent events (3)
  • — J (O) $7000
  • — C (S) $0
  • — Z (S) $0

1910.421 D02

Other-than-serious 1 instance 3 exposed
Issued
Jun 3, 2015
Abate by
Jun 11, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.421(d)(2): Planning of a diving operation did not include an assessment of the safety and health aspects of surface and underwater conditions, is applicable to the Construction Standard 29 CFR 1926.1071 which incorporates the General Industry Requirements:    On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not assess the manmade hazards of the underwater conditions such as, but not limited to, the jagged edges of metal and projections of rebar, marine life and the current caused by the water intakes of the nearby power plant in the diving location, and natural hazards such as the currents, water turbidity and tides.
Recent events (3)
  • — J (O) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.422 C01 I

Serious Gravity 10 1 instance 10 exposed
Issued
Jun 3, 2015
Abate by
Jun 22, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.422(c)(1)(i): An operational two-way voice communication system was not provided during a surface supplied air or mixed-gas between the diver and a dive team member at the dive location, is applicable to the Construction Standard 29 CFR 1926.1081 which incorporates the General Industry Requirements:  On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not ensure an operational two-way voice communication system was used between the divers and a dive team member when performing surface-supplied air diving operations.
Recent events (3)
  • — J (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.424 C02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jun 3, 2015
Abate by
Jun 9, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.424(c)(2): Diver was not line tended from the surface or accompanied by another diver in the water in continuous visual contact during SCUBA diving operation, is applicable to the Construction Standard 29 CFR 1926.1084 which incorporates the General Industry Requirements:  On or about December 20, 2014, at the jobsite, 1 East 11th Street Slip 3, Riviera Beach, Florida 33404, the employer did not provide the diver a line-tender from the surface, or was accompanied by another diver in the water in continuous visual contact during the scuba-diving operation.
Recent events (3)
  • — J (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.424 C03

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jun 3, 2015
Abate by
Jun 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.424(c)(3): A diver was not stationed at the underwater point of entry when SCUBA diving was conducted in enclosed or physically confining spaces, is applicable to the Construction Standard 29 CFR 1926.1084 which incorporates the General Industry Requirements:  On or about December 20, 2014, at the above addressed jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida, the employer did not provide a stationed diver at the underwater point of entry when scuba diving is conducted in enclosed or physically confining spaces.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.425 C02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2015
Abate by
Jun 9, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.425(c)(2): A diver was not stationed at the underwater point of entry when surface-supplied air diving was conducted in enclosed or physically confining spaces  is applicable to the Construction Standard 29 CFR 1926.1085 which incorporates the General Industry Requirements:   On or about December 20th, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not station a diver at the underwater point of entry when surface-supplied air diving is conducted in enclosed or physically confining spaces.
Recent events (3)
  • — J (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.425 C06

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2015
Abate by
Jun 11, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.425(c)(6): A diver-carried reserve breathing gas supply was not provided when the diver was prevented by the configuration of the dive area from ascending directly to the surface during surface-supplied air diving, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements.   On or about December 18th, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer exposed employees to the hazard of drowning and arterial gas embolism, while performing diving operations without an independent backup air supply during underwater diving operations.
Recent events (3)
  • — J (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.430 B01

Other-than-serious 1 instance 10 exposed
Issued
Jun 3, 2015
Abate by
Jun 22, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.430(b)(1): Compressors used to supply air to a diver were not equipped with all of the following:  a volume tank with a check valve on the inlet side, a pressure gauge, a relief valve, and a drain valve, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements:     a) On or about January 27, 2015, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not ensure the Dive Boss air compressor used by divers had a operable tank pressure gauge. The indicating needle of the gauge was stuck at approximately 225 pounds per square inch.      b) On or about January 20, 2015, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not ensure the Brownie air compressor, which does not have a volume tank, was being used to supply air to the divers.
Recent events (3)
  • — J (O) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.430 B04

Other-than-serious 2 instances 10 exposed
Issued
Jun 3, 2015
Abate by
Jun 29, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.430(b)(4): The output of air compressor systems shall be tested for air purity every 6 months by means of samples taken at the connection to the distribution system, except that non-oil lubricated compressors need not be tested for oil mist, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements:    a) On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the supply air of the Dive-Boss air compressor being used by the divers had not been tested for air purity every six months.    b) On or about January 20, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the supply air of the Brownie air compressor being used by the divers had not been tested for air purity every six months.
Recent events (3)
  • — J (O) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.430 C01 I

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jun 3, 2015
Abate by
Jun 15, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.430(c)(1)(i): Breathing gas supply hose(s) did not have a working pressure at least equal to the working pressure of the total breathing gas system, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements:   On or about December 20, 2015, at the above addressed jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer had not tested the breathing gas supply hoses used by the divers, for a working pressure of at least equal to the working pressure of the total breathing gas.
Recent events (3)
  • — J (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.430 C03 II

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jun 3, 2015
Abate by
Jun 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.430(c)(3)(ii): The employer did not ensure the beathing gas supply hose used by the divers was made of kink-resistant were not made of kink-resistant materials, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements:   On or about December 20, 2015, at the jobsite 1 East 11th Street -Slip 3, Riviera Beach, Florida 33404, the employer did not ensure the breathing supply hose used by the divers was made of kink-resistant material.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.430 C01 III

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jun 3, 2015
Abate by
Jun 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.430(c)(1)(iii): Breathing gas supply hose(s) were not tested at least annually to 1.5 times their working pressure, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements:   On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer had not tested the breathing supply hoses used by the divers at least annually to 1.5 times their pressure.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.430 C02 III

Other-than-serious 1 instance 1 exposed
Issued
Jun 3, 2015
Abate by
Jun 9, 2015
Penalty
Initial $0 · Current $7,000
29 CFR 1910.430(c)(2)(iii): Breathing gas supply hose connectors were not resistant to accidental disengagement, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements:      On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not ensure breathing gas supply hose connectors were resistant to accidental disengagement.
Recent events (3)
  • — J (O) $7000
  • — C (S) $0
  • — Z (S) $0

1910.430 J02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2015
Abate by
Jun 11, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29CFR 1910.430(j)(2) Employees without heavy or SCUBA diving gear were not wearing a safety harness, is applicable to the Construction Standard 29 CFR 1926.1090 which incorporates the General Industry Requirements:  On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not ensure employees were wearing a safety harness when performing scuba diving operation.
Recent events (3)
  • — J (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1904.4 A

Deleted Other-than-serious 1 instance 30 exposed
Issued
Jun 3, 2015
Abate by
Jun 22, 2015
Penalty
Initial $1,100 · Current $0 Reduced
29 CFR 1904.4(a): The employer did not keep records of fatalities, injuries and illnesses as required by this part:  On or about December 18th, 2014, at the jobsite, 1 East 11th Street - Slip3, Riviera Beach Florida 33404, the employer did not keep OSHA 300 forms -Log of Work Related Injuries and Illnesses, 300-A form - Summary or Work-Related Injuries and Illnesses; and 301 form - Injury and Illness Incident Report specific for the site.  a) On or about May 23, 2013, an employee was fatally injured at the worksite.  b) On or about June 17, 2013, an employee suffered a leg and ankle injury.  c) On or about March of 2015, an employee injured a leg when a gangway to a barge rolled over.
Recent events (3)
  • — J (O) $0
  • — C (O) $1100
  • — Z (O) $1100

1910.423 B01 I

Deleted Other-than-serious 1 instance 1 exposed
Issued
Jun 3, 2015
Abate by
Jun 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.423(b)(1)(i): The employer did not check the physical condition of the diver after the completion of a dive is applicable to the Construction Standard 29 CFR 1926.1083 which incorporates the General Industry Requirements:  On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not check the physical condition of each diver after completion of their dives.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.423 D01 II

Other-than-serious 1 instance 5 exposed
Issued
Jun 3, 2015
Abate by
Jun 22, 2015
Penalty
Initial $0 · Current $7,000
29 CFR 1910.423(d)(1)(ii): The date, time, and location for each diving operation were not recorded and maintained, is applicable to the Construction Standard 29 CFR 1926.1083 which incorporates the General Industry Requirements:      On or about December 18, 2014, at the jobsite, 1 East 11th Street - Slip 3, Riviera Beach, Florida 33404, the employer did not record or maintain the date, time, and location for each diving operation.
Recent events (3)
  • — J (O) $7000
  • — C (O) $0
  • — Z (O) $0

View Shoreline Foundation, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340150564.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.