MADISON, FL —
OSHA Inspection: STAHL-MEYER FOODS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STAHL-MEYER FOODS, INC. in 294 SW HARVEY GREENE DRIVE, MADISON, FL 32340 (NAICS 311612). OSHA activity number 340154418.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STAHL-MEYER FOODS, INC.
- Site address
- 294 SW HARVEY GREENE DRIVE
- City
- MADISON
- State
- FL
- ZIP
- 32340
- Mailing
- P.O. BOX 937, MADISON, FL 32341
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 125
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.119 J04 II
- Issued
- Mar 31, 2015
- Abate by
- Jun 15, 2015
- Penalty
- Initial $3,375 · Current $1,688 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures did not follow recognized and generally accepted good engineering practices: a. On or about December 22, 2014, in the ammonia refrigeration engine room, the High Pressure Receiver (HPR) tank, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file. b. On or about December 22, 2014, in the ammonia refrigeration engine room, the High Temperature Receiver (HTR V-11) tank, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file. c. On or about December 22, 2014, in the ammonia refrigeration engine room, the High Temperature Receiver (HTR V-13) tank, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file. d. On or about December 22, 2014, in the ammonia refrigeration engine room, the Low Temperature Receiver (LTR) tank, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file. e. On or about December 22, 2014, in the ammonia refrigeration engine room, the Oil Pot V-12, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file. f. On or about December 22, 2014, in the ammonia refrigeration engine room, the Oil Pot V-14, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file. g. On or about December 22, 2014, in the ammonia refrigeration engine room, the Oil Pot V-17, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file. h. On or about December 22, 2014, in the ammonia refrigeration engine room, the Oil Pot V-19, a pressure vessel, did had not been inspected and documented in accordance with the provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Rules, Section VIII, Division 1. A Form U-1, Manufacturer's Data Report for Pressure Vessels was not held on file.
Recent events (2)
- — I (O) $1687.5
- — Z (S) $3375
1910.219 D01
- Issued
- Mar 31, 2015
- Abate by
- Apr 17, 2015
- Penalty
- Initial $2,025 · Current $1,013 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about December 22, 2014, in the ammonia refrigeration engine room, the drive pulleys for liquid recirculation pumps RP-1 and RP-2 were not fully guarded, exposing employees to an ingoing nip point.
Recent events (2)
- — I (O) $1012.5
- — Z (S) $2025
1910.119 J05
- Issued
- Mar 31, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits: a. On or about December 22, 2014, in the ammonia refrigeration engine room, the King Valve was not readily accessible.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 I
- Issued
- Mar 31, 2015
- Abate by
- Apr 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed: a. On or about December 22, 2014, in the ammonia refrigeration engine room, the conductor entering the wall-mounted 115-volt receptacle outlet box was not protected from abrasion at the box cutout in that the outer insulation jacket was torn.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Mar 31, 2015
- Abate by
- Apr 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On or about December 22, 2014, in the ammonia refrigeration engine room, an opening at the bottom of the wall-mounted 115-V receptacle outlet box was not closed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Stahl-Meyer Foods, INC.
View Stahl-Meyer Foods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340154418.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.