MACEDONIA, OH —
OSHA Inspection: M & M CERTIFIED WELDING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of M & M CERTIFIED WELDING, INC. in 556 HIGHLAND RD, MACEDONIA, OH 44056 (NAICS 332710). OSHA activity number 340157882.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & M CERTIFIED WELDING, INC.
- Site address
- 556 HIGHLAND RD
- City
- MACEDONIA
- State
- OH
- ZIP
- 44056
- Mailing
- 556 HIGHLAND RD, MACEDONIA, OH 44056
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 14
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.132 H01
- Issued
- Feb 23, 2015
- Abate by
- Mar 13, 2015
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(h)(1): The employer did not provide personnel protective equipment (PPE) at no cost to employees, except as provided by paragraphs(h)(2) through (h)(6) of this section: Employees are required to provide their own welding helmets, all protective equipment for welding must be paid for by the employer.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.134 C02 I
- Issued
- Feb 23, 2015
- Abate by
- Mar 13, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Employees who are permitted to use half-mask, cartridge respirators during welding on stainless steel and other metals were not provided with a copy of Appendix D of 29 CFR 1910.134.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.134 C02 II
- Issued
- Feb 23, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: No medical evaluations were provided for employees to assure that they were medically able to use respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1026 D01
- Issued
- Feb 23, 2015
- Abate by
- Mar 13, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): No air sampling was done to determine the exposures of employees who weld stainless and other steel that contains chromium, or use welding materials containing chromium.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.1026 L01 III
- Issued
- Feb 23, 2015
- Abate by
- Mar 13, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.1026(l)(1)(iii): The employer did not include chromium (VI) in the hazard communication program, established to comply with the Hazard Communication Standard, 29 CFR 1910.1200, ensure that each employee had access to labels on containers of chromium (VI) and to safety data sheets, and was trained in accordance with the requirements of the Hazard Communication Standard and 29 CFR 1910.1026: Employees who weld stainless steel and were exposed to hexavalent chromium were not trained in the hazards of this chemical.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.1026 L02 I
- Issued
- Feb 23, 2015
- Abate by
- Mar 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1026(l)(2)(i): Prior to initial job assignment to an area where employees were subject to hexavalent chromium exposure, the employer did not ensure that each employee could demonstrate knowledge in the contents of 29 CFR 1910.1026, and the purpose and description of the medical surveillance program required by paragraph (k) of the standard: Employees who weld stainless steel and were exposed to hexavalent chromium were not trained on the contents of the hexavalent chromium standard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1026 L02 II
- Issued
- Feb 23, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1026(l)(2)(ii): The employer did not make a copy of the Chromium (VI) standard, 29 CFR 1910.1026, readily available to all employees who were exposed to chromium (VI): Employees who weld stainless steel and were exposed to hexavalent chromium were not provided a copy of the of the hexavalent chromium standard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at M & M Certified Welding, INC.
View M & M Certified Welding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340157882.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.