WATHENA, KS —
OSHA Inspection: MIDLAND STEEL COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MIDLAND STEEL COMPANY in 202 BEOH LANE, WATHENA, KS 66090 (NAICS 332312). OSHA activity number 340166594.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIDLAND STEEL COMPANY
- Site address
- 202 BEOH LANE
- City
- WATHENA
- State
- KS
- ZIP
- 66090
- Mailing
- P.O. BOX 527, WATHENA, KS 66090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 60
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 6, 2015
- Abate by
- Mar 5, 2015
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On the production floor, the Beam Line Machine did not have specific lockout/tagout procedures developed, exposing employees to a caught in hazard.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.178 A06
- Issued
- Feb 6, 2015
- Abate by
- Mar 5, 2015
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not maintained in a legible condition: In the maintenance area, the Hyster 14,000 capacity forklift had an unreadable dataplace and the controls were not labelled, exposing employees to a struck by hazard.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.179 G01 IV
- Issued
- Feb 6, 2015
- Abate by
- Mar 5, 2015
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.179(g)(1)(iv): Multiple conductor cable was used with a suspended pushbutton station, but the station was not supported in some satisfactory manner that protected the electrical conductors against strain: In the Center Bay, 7C Station, #2 Overhead Crane pendant control has no strain relief, exposing employees to a struck by hazard.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.212 A01
- Issued
- Feb 6, 2015
- Abate by
- Mar 5, 2015
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At Station 5N, the Wells Horizontal Bandsaw was missing guarding exposing approximately 8 1/2 inch of unused portion of the blade to the right of the point of operation, exposing employees to an amputation hazard.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.212 B
- Issued
- Feb 6, 2015
- Abate by
- Mar 5, 2015
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: In the Station 5N area, the WT drill press was not mounted to the ground, exposing employees to a struck by hazard.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.305 B01 II
- Issued
- Feb 6, 2015
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: In Station 5N, the wall mounted circuit breaker cabinet had the front cover unfastened resulting in an opening on the upper right side that was approximately 3 1/2 inches wide, exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
More inspections at Midland Steel Company
View Midland Steel Company's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340166594.