Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDLAND STEEL COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MIDLAND STEEL COMPANY in 202 BEOH LANE, WATHENA, KS 66090 (NAICS 332312). OSHA activity number 340166594.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midland Steel Company — free Get an email when a new federal OSHA severe-injury report for Midland Steel Company is published. One employer, no account, unsubscribe in one click.
Site address
202 BEOH LANE
City
WATHENA
State
KS
ZIP
66090
Mailing
P.O. BOX 527, WATHENA, KS 66090
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
60
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 6, 2015
Abate by
Mar 5, 2015
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On the production floor, the Beam Line Machine did not have specific lockout/tagout procedures developed, exposing employees to a caught in hazard.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

1910.178 A06

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 6, 2015
Abate by
Mar 5, 2015
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not maintained in a legible condition:  In the maintenance area, the Hyster 14,000 capacity forklift had an unreadable dataplace and the controls were not labelled, exposing employees to a struck by hazard.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

1910.179 G01 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 6, 2015
Abate by
Mar 5, 2015
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.179(g)(1)(iv): Multiple conductor cable was used with a suspended pushbutton station, but the station was not supported in some satisfactory manner that protected the electrical conductors against strain:  In the Center Bay, 7C Station, #2 Overhead Crane pendant control has no strain relief, exposing employees to a struck by hazard.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 6, 2015
Abate by
Mar 5, 2015
Penalty
Initial $6,300 · Current $4,410 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  At Station 5N, the Wells Horizontal Bandsaw was missing guarding exposing approximately 8 1/2 inch of unused portion of the blade to the right of the point of operation, exposing employees to an amputation hazard.
Recent events (2)
  • — I (S) $4410
  • — Z (S) $6300

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 6, 2015
Abate by
Mar 5, 2015
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  In the Station 5N area, the WT drill press was not mounted to the ground, exposing employees to a struck by hazard.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 6, 2015
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  In Station 5N, the wall mounted circuit breaker cabinet had the front cover unfastened resulting in an opening on the upper right side that was approximately 3 1/2 inches wide, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

View Midland Steel Company's full OSHA safety record →