Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: P.S. MARCATO ELEVATOR CO., INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of P.S. MARCATO ELEVATOR CO., INC. in 75 WEST END AVENUE, NEW YORK, NY 10023 (NAICS 238290). OSHA activity number 340172451.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch P.S. Marcato Elevator CO., INC. — free Get an email when a new federal OSHA severe-injury report for P.S. Marcato Elevator CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
75 WEST END AVENUE
City
NEW YORK
State
NY
ZIP
10023
Mailing
44-11 ELEVENTH STREET, LONG ISLAND CITY, NY 11101
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
6
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 6, 2015
Abate by
Jul 16, 2015
Penalty
Initial $7,000 · Current $6,500 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.     Location:        75 West End Avenue, New York, NY. Elevator Shaft.     a)  Supervisors did not enforce  the utilization of energy control procedures by employees as they worked in the elevator shafts on the elevators and associated equipment without implementing lockout tagout procedures.    On 1/9/15, an employee was working inside the elevator shaft, at the lobby level, Energy control procedures were not utilized on Elevators 7,8 and 9 when the employee worked in the shaft.
Recent events (3)
  • — F (S) $6500
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C04 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 6, 2015
Abate by
Jul 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section.  Location:    75 West End Avenue, New York, NY. Elevator Shaft.  a) The lockout tag-out procedures , for the work on the elevators and associated equipment,  did not clearly identify all of the specific steps to be followed by employees to isolate and de-energize the elevator system. The procedures provided by the employer by the P.S. Marcato Accident Prevention and Safety manual were general and did not contain a specific statement on the intended use of the procedure, did not contain specific procedural steps for the shutting down, isolating, blocking and securing the elevators and the associated equipment to control hazardous energy, did not contain specific procedural steps for the placement, removal and transfer of lockout devices and responsibility for them and did not contain specific requirements for testing the elevators and associated equipment to determine and verify the effectiveness of lockout devices and other energy control measures.  On 1/9/15, An employee was working inside the elevator shaft, at the lobby level, between shafts 8 and 9.  Elevators number 7 and 9 continued to operate in routine capacity while the employee was in the shaft.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 6, 2015
Abate by
Jul 16, 2015
Penalty
Initial $7,000 · Current $6,500 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.     Location:       75 West End Avenue, New York, NY. Elevator Shaft.    a) The employer did not conduct training for employees to provide them with the knowledge and skills required to safely apply, use and remove energy controls during the work on the elevator and associated equipment during the elevator modernization project.  On 1/9/15, An employee was working inside the elevator shaft, at the lobby level,. Training on the LOTO program and procedures were not utilitzed on Elevators 7,8 and 9 when an employee worked in the shaft.
Recent events (3)
  • — F (S) $6500
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C01

Other-than-serious 1 instance 1 exposed
Issued
Jul 6, 2015
Abate by
Jul 16, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative      Location:    75 West End Avenue, New York, NY. Elevator Shaft.    a)    The employer did not establish a LOTO program to ensure that the elevators and  associated equipment  were not isolated from energy sources and rendered inoperative during the modernization of the elevators.  On 1/9/2015, an employee was working inside the elevator shaft, at the lobby level, between shafts at the lobby level. Elevators 7,8 and 9 were not locked out while the employee worked in the shaft.
Recent events (3)
  • — F (O) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 6, 2015
Abate by
Jul 16, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed.      Location:    75 West End Avenue, New York, NY. Elevator Shaft.    a)  The employer did not ensure through periodic inspection that the procedures and requirements of this standard are being followed.  On 1/9/15, An employee was working inside the elevator shaft, at the lobby level. Periodic or annual inspections of the Energy Control Procedures were not utilized on Elevators 7,8 and 9 when an employee worked in the shaft.
Recent events (3)
  • — F (O) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.23 C01

Other-than-serious 1 instance 1 exposed
Issued
Jul 6, 2015
Abate by
Jul 16, 2015
Penalty
Initial $13,860 · Current $5,000 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder.    Location:    75 West End Avenue, New York, NY. Elevator Shaft.    a)    On 1/9/2015 an employee was working inside the elevator shaft, at the lobby level. No form of fall protection was being utilized by the employee in the shaft.    P.S. Marcato Elevator Co., Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 1910.23(c)(1), which was contained in OSHA inspection number 902622, citation number 01, item number 01 and was affirmed as a final order on 12/02/2013, with respect to a workplace located at 61 Broadway,  New York, NY 10006.
Recent events (3)
  • — F (O) $5000
  • — C (R) $13860
  • — Z (R) $13860

View P.S. Marcato Elevator CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340172451.