COLUMBIA, MO —
OSHA Inspection: CELL PAK
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CELL PAK in 5301 PARIS ROAD, COLUMBIA, MO 65202 (NAICS 425120). OSHA activity number 340176999.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CELL PAK
- Site address
- 5301 PARIS ROAD
- City
- COLUMBIA
- State
- MO
- ZIP
- 65202
- Mailing
- 1029 TECHNOLOGY PARK DR, GLEN ALLEN, VA 23059
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 425120
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Apr 1, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Throughout facility: The machine specific lockout tagout procedures were not adequate for machines that were hard wired in, such as, but not limited to, the Front Dust House and the Rear Dust House. The machine specific procedures did not include the start up and shut down procedures for each individual machine specific procedure.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C06 I
- Issued
- Apr 1, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Throughout facility: The employer failed to conduct a periodic inspection of the lockout tagout program at least annually.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Apr 1, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The training program of the employer did not include all the training elements listed under Items A-C of 29 CFR 1910.147(c)(7)(i): (a) Throughout facility: The employer in the written lockout tagout program did not address training of employees and did not differentiate between authorized and affected employees for lockout tagout.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A01 I
- Issued
- Apr 1, 2015
- Abate by
- May 6, 2015
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not connected to all boxes, fittings, and cabinets to provide effective electrical continuity: (a) Exterior Cell Pak Manager's Office Exterior Wall: Employees were exposed to electrical hazards as the metal conduit was not connected to the electrical panel box for the Lab and Lights.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
More inspections at Cell PAK
View Cell PAK's full OSHA safety record →
More inspections in this industry (NAICS 425120)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340176999.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.