MILTON, PA —
OSHA Inspection: CLARK TECHNOLOGY SYSTEMS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CLARK TECHNOLOGY SYSTEMS INC. in 57 N. INDUSTRIAL PARK RD., MILTON, PA 17847 (NAICS 332999). OSHA activity number 340193028.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLARK TECHNOLOGY SYSTEMS INC.
- Site address
- 57 N. INDUSTRIAL PARK RD.
- City
- MILTON
- State
- PA
- ZIP
- 17847
- Mailing
- 159 HARVEYS LANE, MILTON, PA 17847
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 15
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.94 A06
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1910.94(a)(6): The air for abrasive-blasting respirators was not free of harmful quantities of dusts, mists, or noxious gases, and did not meet the requirements for air purity set forth in 29 CFR 1910.134(i): a) Outside Blasting Area: The air supply to the blasting hood was not monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 PPM, on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (S) $1360
- — Z (S) $1360
1910.107 B05 IV
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) Paint Shop: There were no approved automatic sprinklers on the downstream and upstream sides of the filters within the spray paint building, as observed on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
1910.107 B05 I
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth(s) to indicate or ensure that the required air velocity was maintained: Paint Shop: There were no visible gauges, audible alarms or pressure activated devices installed on the spray paint building ventilation system to indicate or ensure that the required air velocity was maintained, as observed on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.244 B
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1910.244(b): Abrasive blast cleaning nozzle(s) were not equipped with an operating valve which had to be held open manually: a) Outside Blasting Area: The manually operated safety handle on the Empire abrasive blasting nozzle was defeated by a plastic zip tie, as observed on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (S) $1360
- — Z (S) $1360
1910.106 D03 II A
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $1,020 · Current $850 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): The door of the metal storage cabinet(s) for flammable and combustible liquids was not provided with a three point lock: a) Storage Trailer: A door on a flammable storage cabinet (VX Cabinet) was missing the handle and door locking mechanism, as observed on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (S) $850
- — Z (S) $1020
1910.37 B06
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a) Production Area: Each of the exit signs (3) were not illuminated to a surface value of at least five foot candles by a reliable light source, as observed on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G02
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Production area: Employees did not receive training in the use of fire extinguishers and the hazards involved with incipient stage fire fighting at least annually, on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Production area: A relocatable power tap, used for battery recharging, was connected in series (daisy chained) with an extension cord, as observed on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Apr 10, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer: a) Production area: Employees did not receive training on the new labeling elements and new SDS format, on or about March 11, 2015. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Clark Technology Systems INC.
View Clark Technology Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340193028.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.