OSHA Inspection: STEEL FABRICATION SERVICES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of STEEL FABRICATION SERVICES, INC. in 2408 FRUITLAND AVENUE, FARMERS BRANCH, TX 75234 (NAICS 332999). OSHA activity number 340194182.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Steel Fabrication Services, INC. — free Get an email when a new federal OSHA severe-injury report for Steel Fabrication Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2408 FRUITLAND AVENUE
City
FARMERS BRANCH
State
TX
ZIP
75234
Mailing
2408 FRUITLAND AVENUE, FARMERS BRANCH, TX 75234
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
25
Ownership type
A

1 citation on file for this inspection.

1910.95 C01

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 13, 2015
Abate by
Jul 20, 2015
Penalty
Initial $3,080 · Current $3,080

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equaled or exceeded an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  The employer does not administer a continuing, effective hearing conservation program whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent.  This violation occurred on or about January 23, 2015, in the metal shop; where the employer did not administer a hearing conservation program for employee noise exposures that exceeded an 8-hour TWA of 85 dBA, based on an 80 db threshold:   (a) A fitter employee was exposed to continuous noise levels at 102.7% of the permissible 8-hour TWA.  The equivalent level of 102.7% is approximately 90.1 dBA.  Sampling was performed for 479 minutes during one shift.  Zero exposure was assumed for the 1 minute not sampled.    (b) A welder employee was exposed to continuous noise levels at 79.99% of the permissible 8-hour TWA.  The equivalent level of 79.99% is approximately 88.3 dBA.  Sampling was performed for 448 minutes during one shift.  Zero exposure was assumed for the 32 minutes not sampled.
Recent events (1)
  • — Z (S) $3080

View Steel Fabrication Services, INC.'s full OSHA safety record →