Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEBRASKA WELDING, LTD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEBRASKA WELDING, LTD in 13600 GILES RD., OMAHA, NE 68138 (NAICS 332999). OSHA activity number 340195379.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nebraska Welding, LTD — free Get an email when a new federal OSHA severe-injury report for Nebraska Welding, LTD is published. One employer, no account, unsubscribe in one click.
Site address
13600 GILES RD.
City
OMAHA
State
NE
ZIP
68138
Mailing
13600 GILES RD., OMAHA, NE 68138
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
13
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 10, 2015
Penalty
Initial $1,301 · Current $911 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:                                                                                                     13600 Giles Rd., Omaha, NE 68136 (Processing): The employer did not ensure that adequate machine guarding was provided on machinery including, but not limited to:    a)     Hyd-Mech horizontal bandsaw  the unused portion of the blade was not adequately guarded.
Recent events (2)
  • — I (S) $910.7
  • — Z (S) $1301

1910.303 G01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 10, 2015
Penalty
Initial $1,224 · Current $857 Reduced
29 CFR 1910.303(g)(1)(ii):  Working space about electric equipment rated 600 volts, nominal, or less was used for storage:    13600 Giles Rd., Omaha, NE 68136 (Processing NW Wall): The employer is failing to ensure that materials were not stored in front of working space for an electrical disconnect.
Recent events (2)
  • — I (S) $856.8
  • — Z (S) $1224

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 10, 2015
Penalty
Initial $1,530 · Current $1,071 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:                                                                 13600 Giles Rd., Omaha, NE 68136 (Processing): The employer did not ensure that a flexible cord on the Hyd-Mech Model horizontal bandsaw had proper strain relief.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1530

View Nebraska Welding, LTD's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340195379.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.