Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: E.I. DUPONT DE NEMOURS & CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of E.I. DUPONT DE NEMOURS & CO., INC. in 12501 STRANG RD., LA PORTE, TX 77572 (NAICS 325188). OSHA activity number 340196500.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch E.I. Dupont DE Nemours & CO., INC. — free Get an email when a new federal OSHA severe-injury report for E.I. Dupont DE Nemours & CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
12501 STRANG RD.
City
LA PORTE
State
TX
ZIP
77572
Mailing
P. O. BOX 347, LA PORTE, TX 77572
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
313
Ownership type
A

9 citations on file for this inspection.

1910.119 D

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Jun 19, 2017
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.119(d): The employer did not complete a compilation of written process safety information pertaining to the equipment in the process.    a) This violation was most recently observed on or about January 12, 2015 in the Herbicide Business Unit (HBU) at DuPont Plant located in La Porte, Texas when the employer failed to document and maintain the Process Safety Information (PSI) including the materials of construction for the following process piping:    1. Line # 2" 2511 / 2" 2512 (Extractor Pump Tank Overhead to Vacuum Stripper Column)  2. Line # 2" 3615/ 2" 3615A  (Vacuum Stripper Seal Pot to F3455 Stripped S/T)  3. Line # 3" 3204/2" 3205 (Crystallizer Outlet to Slurry Hold Tank)  4. Line # 3" 3151 (Preheater to Concentrator)    b) This violation was most recently observed on or prior to January 12, 2015 in the Hydrogen Fluoride Unit (HF) at DuPont Plant located in La Porte, Texas when the employer failed to document and maintain the Process Safety Information (PSI) including the materials of construction for the following process piping:   Line # 1526, 2" From Drip Acid Tank Vent to Middle Primary Gas Cooler.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.119 E03 I

Serious Gravity 10 2 instances 10 exposed
Issued
Jul 9, 2015
Abate by
Jun 19, 2017
Penalty
Initial $7,000 · Current $12,675
29 CFR 1910.119(e)(3)(i): The Process Hazard Analysis did not address the hazards of the process;    On or about January 12, 2015, the employer's process hazard analysis was not appropriate to the complexity of the process in that it did not address and control the hazards of the Hexazinone process. The process hazard analysis did not address potential employee exposure to hazardous chemicals and temperatures resulting from  the atmospheric discharge from pressure relief devices on the CHI Condenser Seal Pot and Vacuum Stripper Seal Pot.
Recent events (3)
  • — F (S) $12675
  • — C (S) $7000
  • — Z (S) $7000

1910.119 D03 II

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Aug 25, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices (RAGAGEP).  This violation was most recently observed on or about January 12, 2015, in the Herbicides (Hexazinone) Business Unit at DuPont Plant located in La Porte, Texas, when the employer did not document that atmospheric discharge piping from pressure relief devices on the CHI Condenser Seal Pot and Vacuum Stripper Seal Pot relieved to a safe location and complied with (RAGAGEP) such as the ASME Boiler and Pressure Vessel Code, Section VIII.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.119 F01

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Jun 19, 2017
Penalty
Initial $7,000 · Current $12,675
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information.    a)  This violation was most recently observed on or about January 12, 2015, in the Herbicides (Hexazinone) Business Unit (HBU) at the DuPont Plant located in La Porte, Texas when the employer did not develop and implement written operating procedures  for each operating phase of the Vacuum Stripper Preheater (304-352-21).    b)  On or about January 12, 2015, in the Hydrogen Fluoride Unit (HF) at the DuPont Plant located in La Porte, Texas the employer did not  implement written procedures to maintain on-going integrity of process equipment such as lined process piping (e.g. Teflon-lined piping).
Recent events (3)
  • — F (S) $12675
  • — C (S) $7000
  • — Z (S) $7000

1910.119 J02

Deleted Serious Gravity 10 1 instance 33 exposed
Issued
Jul 9, 2015
Abate by
Aug 25, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.119(j)(2): Written procedures. The employer did not establish and implement written procedures to maintain the on-going integrity of process equipment.  On or about January 12, 2015 in the Hydrogen Fluoride Unit (HF) at DuPont Plant located in La Porte, the employer did not establish and implement written procedures to maintain the on-going integrity of process equipment such as lined process piping (e.g. Teflon-lined piping).
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.119 J04 I

Repeat Gravity 10 4 instances 10 exposed
Issued
Jul 9, 2015
Abate by
Jun 19, 2017
Penalty
Initial $70,000 · Current $126,749
29 CFR 1910.119(j)(4)(i): Inspections and tests was not performed on process equipment.    On or about January 12, 2015, in the Herbicide Business Unit (HBU) at DuPont Plant located in La Porte, Texas, the employer did not perform inspections and test on process piping, including but not limited to;     1)    Line # 2" 2511 / 2" 2512 (Extractor Pump Tank Overhead to Vacuum Stripper Column)  2)    Line # 2" 3615/ 2" 3615A  (Vacuum Stripper Seal Pot to F3455 Stripped S/T)  3)    Line # 3" 3204/2" 3205 (Crystallizer Outlet to Slurry Hold Tank)  4)    Line # 3" 3151 (Preheater to Concentrator)
Recent events (3)
  • — F (R) $126749
  • — C (W) $70000
  • — Z (W) $70000

1910.119 J04 I

Repeat Gravity 10 1 instance 33 exposed
Issued
Jul 9, 2015
Abate by
Jun 19, 2017
Penalty
Initial $35,000 · Current $0 Reduced
29 CFR 1910.119(j)(4)(i): Inspections and tests were not performed on process equipment.    This violation was most recently observed in the Hydrogen Fluoride Unit (HF) at  the DuPont Plant located in La Porte, Texas when inspections and tests were not performed on hydrofluoric acid process piping. The employer did not perform inspections and tests on Line #1526, 2" from the drip acid tank vent to the middle primary gas cooler.     E.I. DuPont De Nemours & Co., Inc. was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent standard 29 CFR 1910.119(j)(4)(i) which is contained in OSHA Inspection Number 313371924, Citation Number 1, Item  Number 2, issued on July 19, 2010 with respect to a workplace located at 901 West DuPont Ave., Belle, WV. This file became Final Order on August 24, 2010.
Recent events (3)
  • — F (R) $0
  • — C (R) $35000
  • — Z (R) $35000

1910.119 J04 II

Repeat Gravity 10 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Jun 19, 2017
Penalty
Initial $70,000 · Current $126,749
29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures shall follow recognized and generally accepted good engineering practices.     On or about January 12, 2015, in the Herbicides (Hexazinone) Business Unit (HBU) at DuPont Plant located in La Porte, Texas, the employer data did not include t-min/t-required and corrosion rate values as stipulated in RAGAGEP such as API 570.
Recent events (3)
  • — F (R) $126749
  • — C (W) $70000
  • — Z (W) $70000

1910.119 J04 III

Repeat Gravity 10 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Jun 19, 2017
Penalty
Initial $70,000 · Current $0 Reduced
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.    On or about January 12, 2015 in the Herbicides (Hexazinone) Business Unit (HBU) at DuPont Plant located in La Porte, Texas,  the employer did not ensure that the frequency of inspections and tests of the Crystallizer (304-326-08) and Vacuum Stripper Preheater (304-352-21) was consistent with applicable manufacturers' recommendations.
Recent events (3)
  • — F (R) $0
  • — C (W) $70000
  • — Z (W) $70000

View E.I. Dupont DE Nemours & CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340196500.