BARSTOW, CA —
OSHA Inspection: URS FEDERAL TECHNICAL SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of URS FEDERAL TECHNICAL SERVICES, INC. in BLDG. 573 PO BOX 110880, BARSTOW, CA 92311 (NAICS 811111). OSHA activity number 340206325.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- URS FEDERAL TECHNICAL SERVICES, INC.
- Site address
- BLDG. 573 PO BOX 110880
- City
- BARSTOW
- State
- CA
- ZIP
- 92311
- Mailing
- BLDG. 573 PO BOX 110880, BARSTOW, CA 92311
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 314
- Ownership type
- A
Citations
19 citations on file for this inspection.
1910.22 A02
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: CWC 226, Small Arms: Employees were exposed to slipping and falling where blast media pellets were not cleaned from the floor in the area next to the blasting machine.
Recent events (3)
- — F (S) $0
- — C (S) $2550
- — Z (S) $2550
1910.23 C01
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $5,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: CWC 223, AAV Finals: Employees were exposed to fall hazards where employees work atop assault amphibious vehicle with surfaces eight feet above the adjacent floor with unguarded edges.
Recent events (3)
- — F (S) $0
- — C (S) $5100
- — Z (S) $5100
1910.37 B02
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Employees exposed to delayed emergency evacuation where exit signs were not posted on either emergency exit door at CWC 226, in the Expeditor Office:.
Recent events (3)
- — F (O) $2550
- — C (S) $2550
- — Z (S) $2550
1910.157 E03
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) CWC 226, Small Arms: Employees exposed to fire related injuries where the employer did not complete an annual inspection of the fire extinguisher. (b) CWC 213, Hydraulics Shop: Employees exposed to fire related injuries where the employer did not complete an annual inspection of the fire extinguisher. (c) CWC 224, LAVS: Employees exposed to fire related injuries where the employer did not complete an annual inspection of the fire extinguisher. (d) CWC 273, MTVR: Employees exposed to fire related injuries where the employer did not complete an annual inspection of the fire extinguisher.
Recent events (3)
- — F (O) $2550
- — C (S) $2550
- — Z (S) $2550
1910.212 A01
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: CWC 213, Hydraulics shop: Employees were exposed to the unguarded horizontal rotating parts of the STR Assembly Machine when fabricating hydraulic hose sections where a method of guarding was not provided to protect the employees.
Recent events (3)
- — F (S) $0
- — C (S) $4250
- — Z (S) $4250
1910.215 A04
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $3,400 · Current $3,400
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) CWC 226, Artillery Repair: Employees using grinding machinery were exposed to injury where the work rest was three-sixteenths of an inch from the grinding surface. (b) CWC 223, AAV Finals: Employees using grinding machinery were exposed to injury where the work rest was three-sixteenths of an inch from the grinding surface. (c) CWC 273, MTVR: Employees using grinding machinery were exposed to injury where the left and right work rests were three-sixteenths of an inch from the grinding surface. (d) CWC 273 bldg. SS617: Employees using grinding machinery were exposed to injury where the work rest was one-quarter of an inch from the grinding surface.
Recent events (3)
- — F (O) $3400
- — C (S) $3400
- — Z (S) $3400
1910.215 B09
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $4,250 · Current $2,050 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): Exposure adjustment: Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.) (a) CWC 226, Artillery Repair: Employees using grinding machinery were exposed to injury where the tongue guard was adjusted to five-sixteenths of an inch from the surface of the grinding wheel. (b) CWC 226, Artillery Repair: Employees using grinding machinery were exposed to injury where the tongue guard was adjusted to five-sixteenths of an inch from the surface of the grinding wheel. (c) CWC 271, HMMWV: Employees using grinding machinery were exposed to injury where the tongue guard was adjusted to one and one-half inches from the surface of the grinding wheel. (d) CWC 223, AAV Finals: Employees using grinding machinery were exposed to injury where the tongue guard was removed from the machine. (e) CWC 227, M917 Dump Trucks: Employees using grinding machinery were exposed to injury where the tongue guard was adjusted to seven-sixteenths of an inch from the surface of the grinding wheel. (f) CWC 273, MTVR: Employees using grinding machinery were exposed to injury where the tongue guard was adjusted to three-sixteenths of an inch from the surface of the grinding wheel. (g) CWC 273 bldg. SS617: Employees using grinding machinery were exposed to injury where the tongue guard was adjusted to almost one-half of an inch from the surface of the grinding wheel.
Recent events (3)
- — F (O) $2050
- — C (S) $4250
- — Z (S) $4250
1910.242 B
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $3,400 · Current $3,400
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) CWC 226, Small Arms: Employees exposed to potential injury from the use of compressed air for cleaning at 60 p.s.i. (b) CWC 223, AAV Finals: Employees exposed to potential injury from the use of compressed air for cleaning at 120 p.s.i.
Recent events (3)
- — F (O) $3400
- — C (S) $3400
- — Z (S) $3400
1910.243 B02
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.243(b)(2): Airhose. Hose and hose connections used for conducting compressed air to utilization equipment shall be designed for the pressure and service to which they are subjected. On or about 13 Jan 2015 and times there prior to the employer failed to ensure that air-hoses used in the areas near columns D-30, D-27 were adequate for the location of use exposing employees to struck by hazard from the potential of whipping when the hose breaks.
Recent events (3)
- — F (S) $0
- — C (S) $3400
- — Z (S) $3400
1910.303 B02
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $4,250 · Current $4,250
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling: (a) CWC 272, LVSR Components: Employees exposed to electrical shock and burn hazards where an extension cord was plugged into a power strip to provided 120VAC service to a radio. (b) CWC 221, M88 Section: Employees exposed to electrical shock and burn hazards where an extension cord reel was plugged into a power strip to provided 120VAC service to a radio. (c) CWC 271, HMMWV: Employees exposed to electrical shock and burn hazards where a power strip was plugged into an extension cord to provided 120VAC service to a microwave oven. (d) CWC 113, Material Expeditors room 601: Employees were exposed to electrical shock and burn hazards where a power strip was used to provide 120VAC service to a refrigerator. (e) CWC 113, Material Expeditors room 601: Employees were exposed to electrical shock and burn hazards where a power strip was used to provide 120VAC service to a microwave oven. (f) CWC 113, Material Expeditors bldg. 615: Employees were exposed to electrical shock and burn hazards where a power strip was plugged into an extension cord to provide 120VAC service to a computer. (g) CWC 272, MRAP: Employees were exposed to electrical shock and burn hazards where a microwave oven was plugged into a power strip. (h) CWC 273, MTVR: Employees exposed to electrical shock and burn hazards where a power strip was plugged into an extension cord to provided 120VAC service to a water heater small appliance. (i) CWC 273, MTVR: Employees were exposed to electrical shock and burn hazards where a microwave oven was plugged into a work bench power strip.
Recent events (3)
- — F (O) $4250
- — C (S) $4250
- — Z (S) $4250
1910.303 B07 I
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: CWC 277, MATV: Employees were exposed to electrical shock where an unused opening in an electrical box was covered with black tape.
Recent events (3)
- — F (S) $0
- — C (S) $3400
- — Z (S) $3400
1910.303 G01 II
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $4,250 · Current $4,250
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) CWC 226, Small Arms: Employees were exposed to delayed access to two single throw knife switch electrical boxes where a pallet of shrink wrapped rolls of floor material was stored directly in before the electrical boxes. (b) CWC 226, Small Arms: Employees were exposed to delayed access to a single throw knife switch electrical box where a pallet with a tray of loose wheel parts was stored directly before the electrical box. (c) CWC 273, MTVR: Employees were exposed to delayed access to a single throw knife switch electrical box where a work bench and file cabinet were stored directly before a circuit breaker panel box. (d) CWC 277 near beam D-28 Employees were exposed to delayed access to an electrical panel were a large stand up fan was in front of the panel.
Recent events (3)
- — F (O) $4250
- — C (S) $4250
- — Z (S) $4250
1910.304 B04 II B
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $3,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4: CWC 226, Artillery Repair: Employees were exposed to electrical shock where a 20 amp branch circuit supplying two or more receptacle outlets was supplying a load of 23.1 amps where table S-4 indicates the maximum load is 16 amps.
Recent events (3)
- — F (S) $0
- — C (S) $3400
- — Z (S) $3400
1910.305 G01 IV A
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
2 9 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: CWC 272, LVSR Components: Employees exposed to electrical shock and burn hazards where an extension cord was used to provide 120VAC service to a refrigerator for over 90 days.
Recent events (3)
- — F (S) $0
- — C (S) $2550
- — Z (S) $2550
1910.305 G01 IV D
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: CWC 113, Material Expeditors bldg. 615: Employees exposed to electrical hazards where an extension cord was draped over structural supports on the walls of the building.
Recent events (3)
- — F (S) $0
- — C (S) $2550
- — Z (S) $2550
1910.305 G02 III
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws: On or about 13 April 2015 and times there prior to the employer failed to ensure that at work areas in the cable shop CWC 231 that cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminals screws which by exposing employees to shock or electrocution hazard.
Recent events (3)
- — F (S) $0
- — C (S) $4250
- — Z (S) $4250
1910.334 A02 II
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made. (a) CWC 226, Artillery Repair: Employees were exposed to electrical shock where the employer did not replace a damaged pendant cord. (b) CWC 271, HMMWV: Employees were exposed to electrical shock where the employer did not replace a damaged extension cord. (c) CWC 113, Material Expeditors bldg. 615: Employees were exposed to electrical shock where the employer did not replace a damaged extension cord. (d) CWC 227, M917 Dump Trucks: Employees were exposed to electrical shock where the employer did not replace a damaged extension cord. (e) CWC 123, Maintenance bldg. S634A: Employees were exposed to electrical shock where the employer did not replace a damaged extension cord. (f) In the cable shop employees were exposed to electrical shock from the use of damaged cords as flexible cords and extension cords were not visually inspected before use
Recent events (3)
- — F (S) $0
- — C (S) $4250
- — Z (S) $4250
1910.1200 G08
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: CWC 213, Hydraulics shop: Employees were exposed to the harmful effects of the blast media used in the shop where the employer failed to maintain a copy of the material safety data sheets for the material in the workplace.
Recent events (3)
- — F (O) $2550
- — C (S) $2550
- — Z (S) $2550
1910.1200 F05
- Issued
- Jun 3, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: CWC 226, Small Arms: Employees exposed to potential injury from mislabeled cleaning chemicals used in the workplace where a break-down bottle containing a soap and water solution was labeled Isopropyl Alcohol.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at URS Federal Technical Services, INC.
View URS Federal Technical Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340206325.