GREENWOOD VILLAGE, CO —
OSHA Inspection: PEAK TO PEAK ROOFING AND EXTERIORS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PEAK TO PEAK ROOFING AND EXTERIORS, LLC in 10479 E. FAIR AVE., GREENWOOD VILLAGE, CO 80111 (NAICS 238160). OSHA activity number 340211200.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEAK TO PEAK ROOFING AND EXTERIORS, LLC
- Site address
- 10479 E. FAIR AVE.
- City
- GREENWOOD VILLAGE
- State
- CO
- ZIP
- 80111
- Mailing
- 4155 E. JEWELL AVE. SUITE 1100, DENVER, CO 80222
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.20 B02
- Issued
- Feb 2, 2015
- Abate by
- Mar 20, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) a) On or about January 16, 2015, Peak to Peak Roofing & Exteriors, as a controlling employer, did not provide or maintain programs and conduct effective inspections of the job site to ensure that Eclipse Roofing & Construction (subcontractor) protected their employees from falls greater than 21.0 feet while performing re-roofing activities. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $2000
More inspections at Peak to Peak Roofing and Exteriors, LLC
View Peak to Peak Roofing and Exteriors, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340211200.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.