Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KEENE BUILDING PRODUCTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KEENE BUILDING PRODUCTS in 23750 ST. CLAIR AVE, EUCLID, OH 44117 (NAICS 326199). OSHA activity number 340213404.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keene Building Products — free Get an email when a new federal OSHA severe-injury report for Keene Building Products is published. One employer, no account, unsubscribe in one click.
Site address
23750 ST. CLAIR AVE
City
EUCLID
State
OH
ZIP
44117
Mailing
23750 ST. CLAIR AVE, EUCLID, OH 44117
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
23
Ownership type
A

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 8 exposed
Issued
Apr 1, 2015
Abate by
Apr 21, 2015
Penalty
Initial $2,800 · Current $1,260 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:        On or about January 28, 2015 the employer failed to establish a program for the control of potentially hazardous energies when employees were engaged in maintenance and set up procedures of equipment within the facility. Hazardous energies include but are not limited hydraulic, pneumatic, electrical, mechanical, and thermo. Equipment includes but is not limited to hoppers, coilers, hot melters, conveyors, and augers.
Recent events (3)
  • — F (S) $1260
  • — C (S) $2800
  • — Z (S) $2800

1910.212 A01

Serious Gravity 10 3 instances 6 exposed
Issued
Apr 1, 2015
Abate by
Apr 21, 2015
Penalty
Initial $2,800 · Current $1,260 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) On or about January 28, 2015, the employer failed to ensure that the ingoing nip point created by the conveyor belt and drive roller was effectively guarded on the exit side of Line 1 hot melt production line.    b) On or about January 28, 2015, the employer failed to ensure that the ingoing nip point created by the conveyor belt and drive roller was effectively guarded on the exit side of Line 3 hot melt production line.    c) On or about February 5, 2015, the employer failed to ensure that the ingoing nip point created by the conveyor belt and drive roller was effectively guarded on the exit side of Line 2 hot melt production line.
Recent events (3)
  • — F (S) $1260
  • — C (S) $2800
  • — Z (S) $2800

1910.219 C04 I

Serious Gravity 10 2 instances 6 exposed
Issued
Apr 1, 2015
Abate by
Apr 21, 2015
Penalty
Initial $2,800 · Current $1,260 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:(    a) On or about January 28, 2015, the employer failed to ensure that the projecting shaft ends of the Line 2 product coiler equipment were guarded to prevent employee contact. The shaft ends did not present a smooth edge.      b) On or about January 28, 2015, the employer failed to ensure that the projecting shaft ends of the Line 3 product coiler equipment were guarded to prevent employee contact. The shaft ends did not present a smooth edge.
Recent events (3)
  • — F (S) $1260
  • — C (S) $2800
  • — Z (S) $2800

1910.219 F03

Serious Gravity 10 2 instances 6 exposed
Issued
Apr 1, 2015
Abate by
Apr 21, 2015
Penalty
Initial $2,800 · Current $1,260 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:    a) On or about January 28, 2015, the employer failed to ensure that effective guarding was in place over the chain and sprocket drive system of the Line 2 coiling equipment motor. A metal grating basket was welded onto the equipment to cover the chain and sprocket system, however the openings were too large to prevent employee contact.    b) On or about January 28, 2015, the employer failed to ensure that effective guarding was in place over the chain and sprocket drive system of the Line 2 coiling equipment motor. There was no guarding present on the equipment.
Recent events (3)
  • — F (S) $1260
  • — C (S) $2800
  • — Z (S) $2800

1910.303 B07

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 1, 2015
Abate by
Apr 21, 2015
Penalty
Initial $1,600 · Current $720 Reduced
29 CFR 1910.303(b)(7): 29 CFR 1910.303(b)(7):  Electrical equipment was not installed in a neat and workmanlike manner:    On or about January 28, 2015, the employer failed to ensure that the electrical equipment installed on the Line 2 coiler equipment was installed in a neat and workmanlike manner. Live wiring was routed through a conduit and to a junction box which was not secured as well as wiring not encased entirely in conduit.
Recent events (3)
  • — F (S) $720
  • — C (S) $1600
  • — Z (S) $1600

1910.305 D01

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 1, 2015
Penalty
Initial $2,800 · Current $1,260 Reduced
29 CFR 1910.305(d)(1): Switchboards with exposed live parts were not located in permanently dry locations and accessible only to qualified persons:    On or about January 28, 2015 the employer failed to ensure that only qualified persons accessed the switchboard control panel of the  line 1 hot melt equipment.
Recent events (3)
  • — F (S) $1260
  • — C (S) $2800
  • — Z (S) $2800

1910.305 G01 IV A

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 1, 2015
Abate by
Apr 21, 2015
Penalty
Initial $1,200 · Current $540 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:      a) On or about February 5, 2015, a flexible cord supplying 120v power from a receptacle to the motor of the line 2 coiling equipment was used in lieu of permanent wiring.
Recent events (3)
  • — F (S) $540
  • — C (S) $1200
  • — Z (S) $1200

View Keene Building Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340213404.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.