Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A. DUIE PYLE INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A. DUIE PYLE INC. in 87 AIRCRAFT ROAD, SOUTHINGTON, CT 06489 (NAICS 484110). OSHA activity number 340215243.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A. Duie Pyle INC. — free Get an email when a new federal OSHA severe-injury report for A. Duie Pyle INC. is published. One employer, no account, unsubscribe in one click.
Establishment
A. DUIE PYLE INC.
Site address
87 AIRCRAFT ROAD
City
SOUTHINGTON
State
CT
ZIP
06489
Mailing
87 AIRCRAFT ROAD, SOUTHINGTON, CT 06489
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.106 E02 IV D

Serious Gravity 5 3 instances 4 exposed
Issued
Mar 27, 2015
Penalty
Initial $4,950 · Current $2,723 Reduced
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:  Maintenance Shop:  On, or about, January 29, 2015, the following drums of flammable liquids had not been provided with self-closing valves:  A.  A pink 55 gallon drum that contained diesel fuel, a Category 3 flammable liquid. B.  A 55 gallon drum that contained Brakleen, a Category 2 flammable liquid. C.  A blue 55 gallon drum that contained Camco windshield washer fluid, a Category 3 flammable liquid.
Recent events (2)
  • — I (S) $2722.5
  • — Z (S) $4950

1910.106 E06 I

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:  Maintenance Shop:  On, or about, January 29, 2015, the following drums of flammable liquids were not grounded:  A.  A pink 55 gallon drum that contained diesel fuel, a Category 3 flammable liquid. B.  A 55 gallon drum that contained Brakleen, a Category 2 flammable liquid.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.169 A02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 27, 2015
Penalty
Initial $3,960 · Current $2,178 Reduced
29 CFR 1910.169(a)(2)(i): Air receivers were not constructed in accordance with the 1968 edition of the A.S.M.E. Boiler and Pressure Vessel Code, Section VIII, which is incorporated by reference as specified in 1910.6:   Maintenance Shop:  On, or about, January 29, 2015, the air tank provided on the Balcrank Model 1200-003 Lube Caddy that was used to pressurize fuel lines after changing filters was not manufactured in accordance with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code.
Recent events (2)
  • — I (S) $2178
  • — Z (S) $3960

1910.304 G05

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 27, 2015
Penalty
Initial $4,950 · Current $2,723 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    Maintenance Shop:  On, or about, January 29, 2015, the ground pin was missing from the plug provided on the Associated Model 6009 Fastcharger battery charger.
Recent events (2)
  • — I (S) $2722.5
  • — Z (S) $4950

1910.305 G01 IV A

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 27, 2015
Penalty
Initial $7,920 · Current $5,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:      Maintenance Shop:  On, or about, January 29, 2015, flexible cords were used in lieu of permanent wiring in the following locations:    A.  Far Wall of Shop:  A blue extension cord was used to energize a black relocatable power tap that in turn energized several battery chargers and a second relocatable power tap.    B.  Base of Mezzanine Stairs:  An orange extension cord was used to energize a series of power taps and equipment used at a large tool box.    A. Duie Pyle, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 316007822, Citation Number 1, Item Number 2 and was affirmed as a Final Order on March 23, 2012, with respect to a workplace located at Southington, Connecticut.
Recent events (2)
  • — I (S) $5000
  • — Z (R) $7920

1910.1200 F05 II

Other-than-serious 2 instances 50 exposed
Issued
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  On, or about, January 29, 2015, in the following locations, storage containers were not provided with appropriate hazard warning labels:  A.  Maintenance Shop:  A pink 55 gallon drum that contained diesel fuel, a Category 3 flammable liquid.  B.  Wash Bay:  A tote that contained TerraCair Ultrapure Diesel Exhaust Fluid, an irritant.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View A. Duie Pyle INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340215243.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.