SOUTHINGTON, CT —
OSHA Inspection: A. DUIE PYLE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A. DUIE PYLE INC. in 87 AIRCRAFT ROAD, SOUTHINGTON, CT 06489 (NAICS 484110). OSHA activity number 340215243.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. DUIE PYLE INC.
- Site address
- 87 AIRCRAFT ROAD
- City
- SOUTHINGTON
- State
- CT
- ZIP
- 06489
- Mailing
- 87 AIRCRAFT ROAD, SOUTHINGTON, CT 06489
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484110
- Employees
- 150
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 E02 IV D
- Issued
- Mar 27, 2015
- Penalty
- Initial $4,950 · Current $2,723 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: Maintenance Shop: On, or about, January 29, 2015, the following drums of flammable liquids had not been provided with self-closing valves: A. A pink 55 gallon drum that contained diesel fuel, a Category 3 flammable liquid. B. A 55 gallon drum that contained Brakleen, a Category 2 flammable liquid. C. A blue 55 gallon drum that contained Camco windshield washer fluid, a Category 3 flammable liquid.
Recent events (2)
- — I (S) $2722.5
- — Z (S) $4950
1910.106 E06 I
- Issued
- Mar 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: Maintenance Shop: On, or about, January 29, 2015, the following drums of flammable liquids were not grounded: A. A pink 55 gallon drum that contained diesel fuel, a Category 3 flammable liquid. B. A 55 gallon drum that contained Brakleen, a Category 2 flammable liquid.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.169 A02 I
- Issued
- Mar 27, 2015
- Penalty
- Initial $3,960 · Current $2,178 Reduced
General-duty citation text
29 CFR 1910.169(a)(2)(i): Air receivers were not constructed in accordance with the 1968 edition of the A.S.M.E. Boiler and Pressure Vessel Code, Section VIII, which is incorporated by reference as specified in 1910.6: Maintenance Shop: On, or about, January 29, 2015, the air tank provided on the Balcrank Model 1200-003 Lube Caddy that was used to pressurize fuel lines after changing filters was not manufactured in accordance with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code.
Recent events (2)
- — I (S) $2178
- — Z (S) $3960
1910.304 G05
- Issued
- Mar 27, 2015
- Penalty
- Initial $4,950 · Current $2,723 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Maintenance Shop: On, or about, January 29, 2015, the ground pin was missing from the plug provided on the Associated Model 6009 Fastcharger battery charger.
Recent events (2)
- — I (S) $2722.5
- — Z (S) $4950
1910.305 G01 IV A
- Issued
- Mar 27, 2015
- Penalty
- Initial $7,920 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Maintenance Shop: On, or about, January 29, 2015, flexible cords were used in lieu of permanent wiring in the following locations: A. Far Wall of Shop: A blue extension cord was used to energize a black relocatable power tap that in turn energized several battery chargers and a second relocatable power tap. B. Base of Mezzanine Stairs: An orange extension cord was used to energize a series of power taps and equipment used at a large tool box. A. Duie Pyle, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 316007822, Citation Number 1, Item Number 2 and was affirmed as a Final Order on March 23, 2012, with respect to a workplace located at Southington, Connecticut.
Recent events (2)
- — I (S) $5000
- — Z (R) $7920
1910.1200 F05 II
- Issued
- Mar 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: On, or about, January 29, 2015, in the following locations, storage containers were not provided with appropriate hazard warning labels: A. Maintenance Shop: A pink 55 gallon drum that contained diesel fuel, a Category 3 flammable liquid. B. Wash Bay: A tote that contained TerraCair Ultrapure Diesel Exhaust Fluid, an irritant.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at A. Duie Pyle INC.
View A. Duie Pyle INC.'s full OSHA safety record →
More inspections in this industry (NAICS 484110)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340215243.