Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KELLEY STEEL ERECTORS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KELLEY STEEL ERECTORS INC. in 3600 GEYERS CHAPEL ROAD, WOOSTER, OH 44691 (NAICS 238120). OSHA activity number 340263201.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kelley Steel Erectors INC. — free Get an email when a new federal OSHA severe-injury report for Kelley Steel Erectors INC. is published. One employer, no account, unsubscribe in one click.
Site address
3600 GEYERS CHAPEL ROAD
City
WOOSTER
State
OH
ZIP
44691
Mailing
7220 DIVISION STREET, BEDFORD, OH 44146
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
80
Ownership type
A

2 citations on file for this inspection.

1926.252 B

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2015
Penalty
Initial $4,900 · Current $3,920 Reduced
29 CFR 1926.252(b): When debris was dropped through holes in the floor without the use of chutes, the area onto which the material(s) were dropped was not completely enclosed with barricades not less than 42 inches high and not less 6 feet back from the projected edge of the opening above:     On or about January 26, 2015 at a worksite located at 3600 Geyers Chapel Road Wooster, OH, during steel erection activities including but not limited to cutting an opening in metal deck floor and removing construction debris, the employer did not ensure the area onto which material is dropped was enclosed with barricades, six feet back from the opening above, and posted with signs.
Recent events (2)
  • — I (S) $3920
  • — Z (S) $4900

1926.760 A01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:   On or about January 26, 2015 at a worksite located at 3600 Geyers Chapel Road Wooster, OH, during steel erection activities including but not limited to cutting an opening in metal deck floor and removing construction debris, the employer did not ensure all employees using the elevated steel grating platform to remove debris were protected from fall hazards approximately 17 feet by using a fall protection system/device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

View Kelley Steel Erectors INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340263201.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.