OSHA Inspection: NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, POINT ADAMS SHOP FACILITY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, POINT ADAMS SHOP FACILITY in 200 LAKE DRIVE, HAMMOND, OR 97121 (NAICS 811490). OSHA activity number 340280205.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Oceanic and Atmospheric Administration, Point Adams Shop Facility — free Get an email when a new federal OSHA severe-injury report for National Oceanic and Atmospheric Administration, Point Adams Shop Facility is published. One employer, no account, unsubscribe in one click.
Site address
200 LAKE DRIVE
City
HAMMOND
State
OR
ZIP
97121
Mailing
PO BOX 155, HAMMOND, OR 97121
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811490
Employees
2
Ownership type
D

6 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 3, 2015
Abate by
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) On February 2, 2015 the inspection revealed that the roll forming/bending machine was not provided with at least one of the following methods of point of operation guarding: a point of operation guard, a point of operation device, a point of operation awareness barrier (if a point of operation guard or device is not feasible), or an emergency stop device. The roll forming/bending machine was located in the middle of the shop bay at the time of the inspection.   (b) On February 2, 2015 the inspection revealed that the Cincinnati Bickford radial drill did not have a point of operation guard. The drill was located in the mill room.
Recent events (1)
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:   (a) On February 2, 2015 the inspection revealed that employees were potentially exposed to serious injury from an unguarded horizontal shaft on the Cincinnati Bickford drill press located in the mill room.
Recent events (1)
  • — Z (S) $0

1910.219 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s)   (a) On February 2, 2015 the inspection revealed that employees were potentially exposed to serious injury from an unguarded vertical screw shaft on the Cincinnati Bickford radial drill located in the mill room.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 3, 2015
Abate by
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half-hour.  (a) On February 2, 2015 the inspection revealed that oxygen and acetylene cylinders were stored within about 3 feet of each other and were not separated by a fire resistant barrier, potentially exposing employees to serious injury in the event of a fire. The storage cages were located in the center of the work bay at 200 Lake Drive in Hammond, Oregon.
Recent events (1)
  • — Z (S) $0

1910.254 B04 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.254(b)(4)(iv): Terminals for welding leads were not protected from accidental contact by personnel or metal objects:   (a) On February 2, 2015 the inspection revealed that employees were potentially exposed to serious injury from electric shock because the terminals for welding leads on the Lincoln Arc Welder (flux core welder) were not protected from accidental contact. The Lincoln Arc Welder was located in the welding area of the shop at the time of the inspection.
Recent events (1)
  • — Z (S) $0

1910.303 B07 IV

Other-than-serious 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Mar 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.254(c)(1): Installation of arc welding equipment including power supply was not in accordance with the requirements of Subpart S, 29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  (a) On February 2, 2015 the inspection revealed that the outer insulation on the power cord for Lincoln Arc Welder was damaged. The Lincoln Arc Welder was located in the welding area of the shop at the time of the inspection.
Recent events (1)
  • — Z (O) $0

View National Oceanic and Atmospheric Administration, Point Adams Shop Facility's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340280205.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.