Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCSHANE WELDING COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCSHANE WELDING COMPANY, INC. in 12 PORT ACCESS RD., ERIE, PA 16507 (NAICS 332439). OSHA activity number 340348895.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcshane Welding Company, INC. — free Get an email when a new federal OSHA severe-injury report for Mcshane Welding Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12 PORT ACCESS RD.
City
ERIE
State
PA
ZIP
16507
Mailing
12 PORT ACCESS RD., ERIE, PA 16507
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332439
Employees
38
Ownership type
A

7 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 7, 2015
Abate by
Sep 2, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, pinch points, and moving parts:   A.) McShane Welding Company, Inc. - Wysong Shear Division III Area: On or about 2/10/2015, the hold downs on the shear were not properly guarded by the shear's fixed barrier guard.  Employees could reach under the guard to the area in, around, and under the hold downs.  B.) McShane Welding Company, Inc. - Wysong Shear Division III Area: On or about 2/10/2015, the back side of the shear was not guarded by a barrier, guardrail, fence, and/or chain devices.  The condition potentially exposed employees to the shears moving sections/components and metal material that falls from the back of the machine during the shearing action.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2015
Abate by
Sep 2, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   A.) McShane Welding Company, Inc. - Advantage Press Brake 7606/8 - Division III Area: On or about 2/10/2015, the press brake was not equipped with any point of operation guarding.  The press performed functions that included but were not limited bending sheet metal for electrical boxes.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.217 C02 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2015
Abate by
Sep 2, 2015
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s):  A.) McShane Welding Company, Inc. - Division III Area -- Niagara Press: On or about 2/10/2015, the opening in the yellow colored fixed barrier guard was too large in that employees could reach through the guard to the Point of Operation.  The press was utilized for activities that included but were not limited to punching thin sheets of metal for electrical boxes and shaping hooks.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3500

1910.217 C02 I B

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2015
Abate by
Sep 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(i)(b): Point of operation guard(s) on mechanical power press(es) did not conform to the maximum permissible opening(s) specified in Table 10 O-10:  A.) McShane Welding Company, Inc. - Division III Area -- Niagara Press: On or about 2/10/2015, the opening in the yellow colored fixed barrier guard did not conform to the requirements noted in the 29 CFR 1910.217 Table O-10.  The opening in the guard was at least 8-inches by 8-inches with a distance from the edge of the guard to the die of approximately 1-inch to 1.5 inches.  Table O-10 specifies a maximum guard opening of only 1/4 to 3/8-inches for a 1-inch to 1.5 inch distance. The press was utilized for activities that included but were not limited to punching thin sheets of metal for electrical boxes and shaping hooks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C02 I D

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2015
Abate by
Sep 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(i)(d): Point of operation guard(s) on mechanical power press(es) did not utilized fasteners not readily removable, so as to create minimize the possibility of misuse or removal of essential parts:  A.) McShane Welding Company, Inc. - Division III Area -- Niagara Press: On or about 2/10/2015, the yellow colored fixed barrier guard was not outfitted with special fasteners to prevent it from being by-passed or easily moved out of the way.  The guard was equipped with a simple latching device which allowed the guard to moved to the side with little effort. The press was utilized for activities that included but were not limited to punching thin sheets of metal for electrical boxes and shaping hooks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 7, 2015
Abate by
Sep 2, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  A.) McShane Welding Company, Inc. - Division III Area: On or about 2/10/2015, items including but not limited to metal panels, bags, a box, and several 5-gallon buckets of Mobile product were stored in front of and around the electrical panel box.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.22 D01

Other-than-serious 1 instance 20 exposed
Issued
Aug 7, 2015
Abate by
Sep 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  A.) McShane Welding Company, Inc. - Mezzanine Storage Area/East Side of Production Shop: On or about 2/10/2015, the mezzanine storage area was not marked with approved load limit signs.  The area was utilized for general storage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mcshane Welding Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340348895.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.