TEMPE, AZ —
OSHA Inspection: USGS, ARIZONA WATER SCIENCE CENTER, TEMPE FIELD OFFICE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of USGS, ARIZONA WATER SCIENCE CENTER, TEMPE FIELD OFFICE in 1769 W. UNIVERSITY DRIVE, SUITE 175, TEMPE, AZ 85281 (NAICS 924110). OSHA activity number 340367689.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 1769 W. UNIVERSITY DRIVE, SUITE 175
- City
- TEMPE
- State
- AZ
- ZIP
- 85281
- Mailing
- 1769 W. UNIVERSITY DRIVE, SUITE 175, TEMPE, AZ 85281
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924110
- Employees
- 10
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.106 D02 I
- Issued
- Mar 6, 2015
- Abate by
- Mar 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(2)(i): Approved containers and/or portable tanks were not used for the storage of flammable liquids: (a) Flammable cabinet, Warehouse Shop: On or about February 11, 2015 and at times prior thereto, gasoline was stored in "UL Classified" (unapproved) plastic containers.
Recent events (1)
- — Z (S) $0
1910.151 C
- Issued
- Mar 6, 2015
- Abate by
- Apr 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Laboratory: On or about February 11, 2015 and at times prior thereto, a functioning eyewash was not provided when hydrochloric acid is use to clean glassware.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Mar 6, 2015
- Abate by
- Apr 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Warehouse Shop: On or about February 11, 2015 and at times prior thereto, the rotating chucks of the Craftsman 15-1/2 inch drill press and Craftsman 10 inch drill press were not guarded.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Mar 6, 2015
- Abate by
- Mar 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Warehouse Shop: On or about February 11, 2015 and at times prior thereto, the distance between the abrasive wheel periphery and the tongue guard on the Craftsman 1/2-inch grinder was approximately 1 inch.
Recent events (1)
- — Z (S) $0
1910.253 B04 III
- Issued
- Mar 6, 2015
- Abate by
- Mar 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at lest one-half hour: a) Warehouse Shop: On or about February 11, 2015 and at times prior thereto, oxygen cylinders were stored next to acetylene cylinders.
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Mar 6, 2015
- Abate by
- Apr 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) USGS, AZ Water Science Center, Tempe Field Office: On or about February 11, 2015 and at times prior thereto, a hazard communication program was not developed and implemented for hazardous chemicals.
Recent events (1)
- — Z (O) $0
More inspections at Usgs, Arizona Water Science Center, Tempe Field Office
View Usgs, Arizona Water Science Center, Tempe Field Office's full OSHA safety record →
More inspections in this industry (NAICS 924110)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340367689.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.