HASTINGS, NE —
OSHA Inspection: NOAH'S ARK PROCESSORS
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of NOAH'S ARK PROCESSORS in 1009 W M STREET, HASTINGS, NE 68901 (NAICS 311611). OSHA activity number 340376334.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NOAH'S ARK PROCESSORS
- Site address
- 1009 W M STREET
- City
- HASTINGS
- State
- NE
- ZIP
- 68901
- Mailing
- 1009 W M STREET, HASTINGS, NE 68901
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311611
- Employees
- 300
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 F04
- Issued
- Mar 27, 2015
- Abate by
- Apr 15, 2015
- Penalty
- Initial $4,250 · Current $3,400 Reduced
General-duty citation text
29 CFR 1910.147(f)(4): During shift or personnel changes, specific procedures were not utilized to ensure the continuity of lockout or tagout protection, including provision for the orderly transfer of lockout or tagout devices between off-going and oncoming personnel: The employer is failing to inform second shift personnel that are engaged in Lock-out/Tag-out activities in their facility of their responsibility during shift changes. The current program does not address the requirements of this subpart.
Recent events (2)
- — I (O) $3400
- — Z (S) $4250
1910.305 B02 I
- Issued
- Mar 27, 2015
- Penalty
- Initial $4,250 · Current $3,400 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: The employer is failing to ensure that employees are protected from electrical hazards. Employees working near or on the electrical circuit breaker panel in the vacuum pump room are exposed to live parts due the front cover not being secured and in place. A screw on the panel was missing and the front panel was hanging away from the box approximately 1½" from the box allowing contact with the wiring inside the panel.
Recent events (2)
- — I (O) $3400
- — Z (S) $4250
More inspections at Noah'S ARK Processors
View Noah'S ARK Processors's full OSHA safety record →
More inspections in this industry (NAICS 311611)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340376334.