Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: USGS, ASTROGEOLOGY SCIENCE CENTER

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of USGS, ASTROGEOLOGY SCIENCE CENTER in 2255 N. GEMINI DR. FACILITES MANAGEMENT ASST, SW REGION, FLAGSTAFF, AZ 86001 (NAICS 927110). OSHA activity number 340394873.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usgs, Astrogeology Science Center — free Get an email when a new federal OSHA severe-injury report for Usgs, Astrogeology Science Center is published. One employer, no account, unsubscribe in one click.
Site address
2255 N. GEMINI DR. FACILITES MANAGEMENT ASST, SW REGION
City
FLAGSTAFF
State
AZ
ZIP
86001
Mailing
2255 N. GEMINI DR. FACILITES MANAGEMENT ASST, SW REGION, FLAGSTAFF, AZ 86001
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
927110
Employees
60
Ownership type
D

8 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 28, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  (a) Machine Shop, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, the "Fresh'nd-Aire" pedestal fan had guard openings of at least 3 inches.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 20 exposed
Issued
Apr 28, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) Wood shop, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, the work rest/abrasive wheel opening was approximately 3/8 inch on the "Tradesman" Model 7065, bench grinder.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 20 exposed
Issued
Apr 28, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Machine Shop, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, the tongue guard/abrasive wheel periphery distance was approximately 1/2 inch on the "Tradesman" Model 7065, bench grinder.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 20 exposed
Issued
Apr 28, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  (a) Automotive Shop, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, a cylinder of oxygen and a cylinder of fuel-gas (acetylene) were stored together. Also, the acetylene cylinder did not have a valve protection cap affixed to the cylinder.
Recent events (1)
  • — Z (S) $0

1910.303 B01 IV

Serious Gravity 1 2 instances 5 exposed
Issued
Apr 28, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1)(iv): Electrical insulation was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  (a) Machine Shop, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, the insulation on the power cord for the Fresh'nd-Aire pedestal fan was damaged which exposed the conductors.   (b) Wood Shop, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, the insulation on the power cord for the Makita belt sander was damaged and covered with vinyl tape.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 28, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) Wood Shop, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, the electrical circuit breaker panel was blocked by lumber stored on a rack.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 28, 2015
Abate by
May 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a) Automotive Shop, USGS, Flagstaff, AZ: On or about February 15, 2015 and at times prior thereto, the flexible cord which supplied power to the workbench was connected to a plug without strain relief being provided.
Recent events (1)
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Apr 28, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  (a) Warehouse, USGS, Flagstaff, AZ: On or about February 12, 2015 and at times prior thereto, the agency did not certify that each forklift operator had been trained and evaluated.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340394873.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.