ENFIELD, CT —
OSHA Inspection: SENIOR AEROSPACE CONNECTICUT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SENIOR AEROSPACE CONNECTICUT in 4 PEERLESS WAY, ENFIELD, CT 06082 (NAICS 336412). OSHA activity number 340419753.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SENIOR AEROSPACE CONNECTICUT
- Site address
- 4 PEERLESS WAY
- City
- ENFIELD
- State
- CT
- ZIP
- 06082
- Mailing
- 4 PEERLESS WAY, ENFIELD, CT 06082
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 81
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.107 B05 IV
- Issued
- Apr 9, 2015
- Abate by
- May 27, 2015
- Penalty
- Initial $2,625 · Current $1,838 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: Spray Booth Area: On, or about, March 19, 2015, the Standard Model BSB-1000-5.8-IAL spray booth that was used when paints and coatings were applied to aircraft parts was not provided with sprinkler protection. Coatings such as, but not limited to, a mixture of Sherwin-Williams Chromated Epoxy Polyamide Primer, a Category 2 flammable liquid and Sherwin-Williams Chromated Epoxy Polyamide Primer Catalyst, a Category 2 flammable liquid, were used.
Recent events (2)
- — I (S) $1837.5
- — Z (S) $2625
1910.107 C09 I
- Issued
- Apr 9, 2015
- Abate by
- May 27, 2015
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1910.107(c)(9)(i): 29 CFR 1910.107(c)(9)(i): All metal parts of piping systems conveying flammable or combustible liquids were not properly electrically grounded in an effective and permanent manner: Spray Booth Area: On, or about, March 19, 2015, the DeVilbiss HVLP spray gun used to apply paints and coatings such as, but limited to, a mixture of Sherwin-Williams Chromated Epoxy Polyamide Primer, a Category 2 flammable liquid and Sherwin-Williams Chromated Epoxy Polyamide Primer Catalyst, a Category 2 flammable liquid, was not grounded.
Recent events (2)
- — I (S) $3430
- — Z (S) $4900
1910.107 G03
- Issued
- Apr 9, 2015
- Abate by
- May 27, 2015
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.107(g)(3): Rags or waste impregnated with finishing material were not deposited in approved metal waste cans immediately after use. Spray Booth Area: On, or about, March 19, 2015, paper filters, stir sticks, rags and other waste material that was used with flammable liquids such as, but not limited to, a mixture of Sherwin-Williams Chromated Epoxy Polyamide Primer, a Category 2 flammable liquid and Sherwin-Williams Chromated Epoxy Polyamide Primer Catalyst, a Category 2 flammable liquid, were discarded into a covered plastic trash receptacle.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.305 B01 I
- Issued
- Apr 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: Tool Grinding: On, or about, February 23, 2015, the flexible cord provided for the light fixture mounted on the Black Diamond tool tip grinder was pulled from the in-line mounted electrical box.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Senior Aerospace Connecticut