MACOMB, IL —
OSHA Inspection: NTN-BOWER CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NTN-BOWER CORPORATION in 711 N BOWER ROAD, MACOMB, IL 61455 (NAICS 332991). OSHA activity number 340420843.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NTN-BOWER CORPORATION
- Site address
- 711 N BOWER ROAD
- City
- MACOMB
- State
- IL
- ZIP
- 61455
- Mailing
- 711 N BOWER ROAD, MACOMB, IL 61455
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332991
- Employees
- 750
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jun 8, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $7,000 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): Employees operating the Takamaz XW-150 Turning Lathes were exposed to amputation hazards while changing the jaws and pads during setup activities. The employer did not identify the hydraulic and pneumatic energy sources and did not specifically explain how to de-energize and isolate those sources.
Recent events (2)
- — I (S) $4500
- — Z (S) $7000
1910.147 D03
- Issued
- Jun 8, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): Employees operating the Takamaz XW-150 Turning Lathes were exposed to amputation hazards while changing the jaws and pads during setup activities and the pneumatic and hydraulic energy was not isolated.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jun 8, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Employees who performed maintenance and setup activities on the Takamaz XW-150 Turning Lathes were exposed to amputation hazards and the employer did not perform periodic inspections of the energy control procedures at least annually and identify deficiencies with the procedure.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.147 C06 II
- Issued
- Jun 8, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: Employees who performed maintenance and setup activities on the Takamaz XW-150 Turning Lathes were exposed to amputation hazards and the employer did not document an inspection of the energy control procedures that included the date of the inspection, the equipment inspected, the names of the employees involved and the name of the person that completed the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Ntn-Bower Corporation
View Ntn-Bower Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332991)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340420843.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.