Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NTN-BOWER CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NTN-BOWER CORPORATION in 711 N BOWER ROAD, MACOMB, IL 61455 (NAICS 332991). OSHA activity number 340420843.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ntn-Bower Corporation — free Get an email when a new federal OSHA severe-injury report for Ntn-Bower Corporation is published. One employer, no account, unsubscribe in one click.
Site address
711 N BOWER ROAD
City
MACOMB
State
IL
ZIP
61455
Mailing
711 N BOWER ROAD, MACOMB, IL 61455
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332991
Employees
750
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 13 exposed
Issued
Jun 8, 2015
Abate by
Aug 24, 2015
Penalty
Initial $7,000 · Current $4,500 Reduced
29 CFR 1910.147(c)(4)(ii):     Energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):     Employees operating the Takamaz XW-150 Turning Lathes were exposed to amputation hazards while changing the jaws and pads during setup activities.  The employer did not identify the hydraulic and pneumatic energy sources and did not specifically explain how to de-energize and isolate those sources.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $7000

1910.147 D03

Serious Gravity 10 1 instance 13 exposed
Issued
Jun 8, 2015
Abate by
Aug 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3):     All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):     Employees operating the Takamaz XW-150 Turning Lathes were exposed to amputation hazards while changing the jaws and pads during setup activities and the pneumatic and hydraulic energy was not isolated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 13 exposed
Issued
Jun 8, 2015
Abate by
Aug 24, 2015
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:     Employees who performed maintenance and setup activities on the Takamaz XW-150 Turning Lathes were exposed to amputation hazards and the employer did not perform periodic inspections of the energy control procedures at least annually and identify deficiencies with the procedure.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

1910.147 C06 II

Serious Gravity 5 1 instance 13 exposed
Issued
Jun 8, 2015
Abate by
Aug 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection:     Employees who performed maintenance and setup activities on the Takamaz XW-150 Turning Lathes were exposed to amputation hazards and the employer did not document an inspection of the energy control procedures that included the date of the inspection, the equipment inspected, the names of the employees involved and the name of the person that completed the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Ntn-Bower Corporation's full OSHA safety record →