COLUMBUS, MS —
OSHA Inspection: JASON INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JASON INDUSTRIES, INC. in 221 FABRITEX DR., COLUMBUS, MS 39702 (NAICS 313230). OSHA activity number 340422443.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JASON INDUSTRIES, INC.
- Site address
- 221 FABRITEX DR.
- City
- COLUMBUS
- State
- MS
- ZIP
- 39702
- Mailing
- 221 FABRITEX DR., COLUMBUS, MS 39702
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 313230
- Employees
- 103
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Mar 25, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Line 22 High Speed Lapper - On or about February 24, 2015 the employer did not include the pneumatics in the energy control procedures.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.147 C06 II
- Issued
- Mar 25, 2015
- Abate by
- Apr 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. (a) Line 22 High Speed Lapper - On or about February 24, 2015 the employer did not certify that periodic inspections were performed or that the certification contained the information as required. -
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Jason Industries, INC.
View Jason Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 313230)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340422443.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.