PHILADELPHIA, PA —
OSHA Inspection: KUUSAKOSKI PHILADELPHIA, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KUUSAKOSKI PHILADELPHIA, LLC in 3150 ORTHODOX STREET, PHILADELPHIA, PA 19137 (NAICS 488991). OSHA activity number 340432624.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KUUSAKOSKI PHILADELPHIA, LLC
- Site address
- 3150 ORTHODOX STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19137
- Mailing
- 3150 ORTHODOX STREET, PHILADELPHIA, PA 19137
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488991
- Employees
- 31
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 A08
- Issued
- Aug 17, 2015
- Abate by
- Aug 21, 2015
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded by either a standard railing with standard toeboard on all exposed sides, or a floor hole cover of standard strength and construction. a) Jobsite: Ring crusher; along railing under in-feed conveyor - Employees conducting recycling activities were exposed to trip and fall hazards from a floor hole missing a guard and/or cover. The floor hole measured 16 x 8 inches. b) Jobsite: Ring crusher; where flexible electrical conduits run through adjacent to the eject door - Employees conducting recycling activities were exposed to trip and fall hazards from a floor hole missing a guard and/or cover. The floor hole measured 13 x 15 1/2 inches. Observed on or about 2/20/15
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.23 E01
- Issued
- Aug 17, 2015
- Abate by
- Aug 21, 2015
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard. a) Jobsite: Ring crusher, front and rear staircase - Employees were conducting recycling operations using stairways with railings missing midrails. b) Jobsite: Ring crusher, under in-feed conveyor - Employees were conducting recycling operations on a platform, approximately 10 feet above ground level, without standard railings. c) Jobsite: Ring crusher, behind anvil motor - Employees were conducting recycling operations on a platform with a broken railing. Observed on or about 2/20/15
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.157 C01
- Issued
- Aug 17, 2015
- Abate by
- Aug 21, 2015
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. a) Jobsite: Locker room - Portable fire extinguishers were not mounted, located, or identified. b) Jobsite: Ground level behind ring crusher - Portable fire extinguisher was not mounted, located, or identified. c) Jobsite: Eddy Current room - Portable fire extinguisher was not mounted, located, or identified. Observed on or about 2/20/15.
Recent events (2)
- — I (O) $3500
- — Z (S) $3500
1910.157 D02
- Issued
- Aug 17, 2015
- Abate by
- Aug 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(d)(2): The employer shall distribute portable fire extinguishers for use by employees on Class A fires so that the travel distance for employees to any extinguisher is 75 feet (22.9 m) or less. a) Jobsite: Locker room - The travel distance to the portable fire extinguishers for use by employees on class A fires was greater than 75 feet. Observed on or about 2/20/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 K02
- Issued
- Aug 17, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(k)(2): Rated load test. Test loads shall not be more than 125 percent of the rated load unless otherwise recommended by the manufacturer. The test reports shall be placed on file where readily available to appointed personnel. a) Jobsite: Ring crusher, aftermath area - The employer did not ensure the overhead 1/2 ton electric chain hoist used during recycling activities was load tested. Chain Hoist Mfr. - Harrington Code# - NER005L Serial - 00076379 Observed on or about 2/20/15.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Kuusakoski Philadelphia, LLC
View Kuusakoski Philadelphia, LLC's full OSHA safety record →
More inspections in this industry (NAICS 488991)
More inspections in PA
Source