Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KUUSAKOSKI PHILADELPHIA, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KUUSAKOSKI PHILADELPHIA, LLC in 3150 ORTHODOX STREET, PHILADELPHIA, PA 19137 (NAICS 488991). OSHA activity number 340432624.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kuusakoski Philadelphia, LLC — free Get an email when a new federal OSHA severe-injury report for Kuusakoski Philadelphia, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3150 ORTHODOX STREET
City
PHILADELPHIA
State
PA
ZIP
19137
Mailing
3150 ORTHODOX STREET, PHILADELPHIA, PA 19137
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488991
Employees
31
Ownership type
A

5 citations on file for this inspection.

1910.23 A08

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 17, 2015
Abate by
Aug 21, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded by either a standard railing with standard toeboard on all exposed sides, or a floor hole cover of standard strength and construction.     a) Jobsite: Ring crusher; along railing under in-feed conveyor - Employees conducting recycling activities were exposed to trip and fall hazards from a floor hole missing a guard and/or cover.  The floor hole measured 16 x 8 inches.      b) Jobsite: Ring crusher; where flexible electrical conduits run through adjacent to the eject door - Employees conducting recycling activities were exposed to trip and fall hazards from a floor hole missing a guard and/or cover.  The floor hole measured 13 x 15 1/2 inches.      Observed on or about 2/20/15
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.23 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 17, 2015
Abate by
Aug 21, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard.    a) Jobsite: Ring crusher, front and rear staircase - Employees were conducting recycling operations using stairways with railings missing midrails.      b) Jobsite: Ring crusher, under in-feed conveyor - Employees were conducting recycling operations on a platform, approximately 10 feet above ground level, without standard railings.     c)  Jobsite: Ring crusher, behind anvil motor - Employees were conducting recycling operations on a platform with a broken railing.     Observed on or about 2/20/15
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.157 C01

Other-than-serious 3 instances 31 exposed
Issued
Aug 17, 2015
Abate by
Aug 21, 2015
Penalty
Initial $3,500 · Current $3,500
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.    a) Jobsite: Locker room - Portable fire extinguishers were not mounted, located, or identified.    b) Jobsite: Ground level behind ring crusher - Portable fire extinguisher was not mounted, located, or identified.    c) Jobsite: Eddy Current room - Portable fire extinguisher was not mounted, located, or identified.      Observed on or about 2/20/15.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $3500

1910.157 D02

Deleted Serious Gravity 5 3 instances 31 exposed
Issued
Aug 17, 2015
Abate by
Aug 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(d)(2): The employer shall distribute portable fire extinguishers for use by employees on Class A fires so that the travel distance for employees to any extinguisher is 75 feet (22.9 m) or less.   a) Jobsite: Locker room - The travel distance to the portable fire extinguishers for use by employees on class A fires was greater than 75 feet.  Observed on or about 2/20/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 K02

Other-than-serious 1 instance 3 exposed
Issued
Aug 17, 2015
Abate by
Aug 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.179(k)(2): Rated load test. Test loads shall not be more than 125 percent of the rated load unless otherwise recommended by the manufacturer. The test reports shall be placed on file where readily available to appointed personnel.   a) Jobsite: Ring crusher, aftermath area  - The employer did not ensure the overhead 1/2 ton electric chain hoist used during recycling activities was load tested.    Chain Hoist Mfr. - Harrington Code# - NER005L Serial - 00076379    Observed on or about 2/20/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kuusakoski Philadelphia, LLC's full OSHA safety record →